KNX switching actuator 8-fold 104600

104600 4010337042273 EAN/GTIN DE 59229780 WEEE

Our best price
$277.64 excl. VAT
$501.42 (-44.63% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Switch actuator 8-fold REG KNX/EIB 16A C-Last 104600 bus system KNX, other bus systems without,... more
KNX switching actuator 8-fold 104600 – Gira – 4010337042273: Switch actuator 8-fold REG KNX/EIB 16A C-Last 104600 bus system KNX, other bus systems without, mounting type REG, width in modular units 8, on-site/manual operation, max. switching capacity 3680W, suitable for C-load, max. number of switching outputs 8, Max. switching current 16A, rated current 16A, with bus coupling, protection class (IP) IP20, KNX switching actuator 8-fold 16 A with manual operation and current measurement for C-loads REG plus REG switching actuators with integrated bus coupling. For switching independently controllable load groups. With manual switch for switching the relay (on off) in parallel or without KNX operation. Connection polyphase. No additional power supply required. Features: Manual actuation of the relays independent of the bus or the switch position indicator. Normally open or normally closed operation. Central switching function. Collective feedback to reduce the bus load. Active or passive (object readable) cyclic feedback function. Feedback can be delayed after bus voltage return. Logical link function for each output. Blocking function can be configured for each channel. Alternatively forced position function for each output. Time functions (switch-on and switch-off delay, staircase lighting function - also with pre-warning function). Inclusion in light scenes possible, max. eight internal scenes per channel can be configured. Memory function for light scenes. Operating hours counter can be activated as an up/down counter with limit value function (limit value can be changed via the bus) for each output. Input monitoring for cyclic update with safety position. Responses to bus voltage failure and return and after ETS programming can be set for each channel. The switching contacts of the switching actuator 8-fold C-Load are specially designed for loads with a capacitive character and the resulting short-term high inrush currents (see technical data). The switching actuator has an integrated current detection. A current measurement can be carried out for each channel. Current detection: measurement of load current for each channel. Threshold values for load monitoring (e.g. message load failure). Independent switching of the eight outputs. Notes : DIN rail mounting. VDE approval according to EN 60669-1, EN 60669-2-1.
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems without
Mounting REG
Width in division units 8th
On-site / manual operation yes
With LED display no
Max. Switching capacity 3680 W
Suitable for C-load yes
Max. Number of switching outputs 4
Max. Switching current 16 A
Rated current 16 A
With bus coupling yes
Modular expansion option no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "KNX switching actuator 8-fold 104600"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.