AFD 1P+N 10A B AFD unit - Miniature circuit breaker 2-p B10A A9FDB7610

Schneider Electric - A9FDB7610 - AFD 1P+N 10A B AFD unit - Miniature circuit breaker 2-p B10A A9FDB7610
Photo source: fig. possibly similar
A9FDB7610 3606481211743 EAN/GTIN DE 33842582 WEEE

Our best price
$134.26 excl. VAT

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
AFD AFDD 1P+N 10A B A9FDB7610 AFD unit tripping characteristic B, number of poles 2, rated... more
AFD 1P+N 10A B AFD unit - Miniature circuit breaker 2-p B10A A9FDB7610 – Schneider Electric – 3606481211743: AFD AFDD 1P+N 10A B A9FDB7610 AFD unit tripping characteristic B, number of poles 2, rated current 10A, rated voltage 230V, rated breaking capacity according to IEC 60947-2 0kA, type of voltage AC, energy limitation class 3, frequency 50Hz, switching neutral conductor, overvoltage category 3, degree of pollution 2, size (according to DIN 43880) 2, width in pitch units 2, installation depth 44mm, additional devices installed at the factory AFD unit, rated switching current additional device 0A, rated voltage additional device 0V, degree of protection (IP) IP20, AFDD - arc fault protection device (AFD) in combination with a miniature circuit breaker, Acti 9 iDPN N Arc. 1-pole+N, 10A, B-characteristic. Breaking capacity 6kA according to EN 60898, operating voltage 230/240V AC. Upon detecting a dangerous serial or parallel arcing fault, the AFDD trips to isolate the faulty feeder from the mains. In addition to protecting against arcing faults, the device protects against short circuits, overloads and mains overvoltages. Range Benefits- Arc faults can result from poor or damaged cable insulation or from faulty connections and can cause a fire. Standards- EN/IEC 62606,IEC 60898-1.
... more
Release characteristic B
Number of poles 2
Rated current 10 A
Rated voltage 230V
Rated breaking capacity according to EN 60898 6 kA
Rated switch-off capacity according to IEC 60947-2 0 kA
Voltage AC
Limiting class 3
Frequency 50 Hz
Coupling neutral conductor yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 44 mm
Rated switching current additional device 0A
Rated voltage additional device 0 V
IP protection) IP20
Size (according to DIN 43880) 2

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "AFD 1P+N 10A B AFD unit - Miniature circuit breaker 2-p B10A A9FDB7610"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.