Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Circuit breaker AFR460C Number of poles (total) 4, number of fused poles 4, rated voltage 400V,... more
Earth leakage circuit breaker C10/0,3A AFR460C – Hager – 3250611015604: Circuit breaker AFR460C Number of poles (total) 4, number of fused poles 4, rated voltage 400V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated current 10A, rated residual current 0.3A, residual current type A, energy limitation class 3, rated switching capacity Icn according to EN 61009-1 10kA , Switch-off characteristic instantaneous, surge current resistance 3kA, voltage type AC, frequency 50 Hz, tripping characteristic C, with locking device, overvoltage category 3, pollution degree 2, ambient temperature during operation -25 ... 40°C, width in division units 4, installation depth 70mm, flush-mounted installation, false tripping protection, Protection class (IP) IP20, connectable conductor cross-section solid 1 ... 25mm², connectable conductor cross-section multi-wire 1 ... 16mm², residual current circuit breaker 4P 10kA C-10A 300mA Hi type. Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with 4-pole circuit breaker for 400 V three-phase circuits and a residual current protection circuit in a compact housing, blue test button and residual current indicator. Simple individual removal from the phase busbar network. Suitable for retrofitting additional equipment. Labeling option directly on the device.
... more
Number of poles (total) 4
Number of secured poles 4
Rated voltage 400V
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Rated current 10 A
Rated fault current 0.3 A
Fault current type A
Limiting class 3
turn-off characteristic instantaneously
Surge current resistance 3 kA
Voltage AC
Frequency 50 Hz
Release characteristic C
Coupling neutral conductor no
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 4
Depth 70 mm
Flush mounting yes
False triggering protection yes
IP protection) IP20