KNX room control unit, G1, 24V, white 207712

207712 4010337014317 EAN/GTIN DE 59229780 WEEE

Our best price
$1,051.29 excl. VAT
$1,329.07 (-20.9% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Room control unit G1 UP 24V white 207712 KNX bus system, other eNet bus systems, flush-mounted... more
KNX room control unit, G1, 24V, white 207712 – Gira – 4010337014317: Room control unit G1 UP 24V white 207712 KNX bus system, other eNet bus systems, flush-mounted installation, with display, status LED, temperature controller, with theft/dismantling protection, central functional unit for transmitters/actuators, other material, other material quality, other surface, surface design not applicable, color white, degree of protection (IP) IP21, Gira G1 24 V glass white The Gira G1 is a multifunctional room operating device for the visualization and operation of a wide range of building functions. For use in the KNX system and in the Gira door communication system or as a client. The range of functions depends on the firmware used. For the precise range of functions, please refer to the Gira online catalog and the technical device documentation. Features: It is operated via a gesture-enabled multi-touch display. Connection and communication depends on the variant via LAN or WLAN. Integrated speaker. Integrated microphone with echo cancellation. Possible uses and combinations: The Gira G1 as a multifunctional room operating device provides the following functions or combinations of functions: KNX room operating device Home station Video client for the following systems Server - HomeServer - eNet - X1 security system Alarm Connect Integration of Internet services Properties as a KNX room operating device: Intuitive to use and end-user customizable user interface. Switching, pressing, dimming (relative and absolute), dimming (incl. dimming RGB, RGBW and Tunable White) blind and roller shutter control, value transmitter, scene extension. Status display, display of date and time, display of inside and outside temperature. Up to 150 functions (six function folders or rooms with up to 25 functions each). Up to 125 weekly timers, each with 10 switching times. Room temperature controller in combination with the optionally available temperature sensor module or KNX devices for room temperature measurement, e.g. B. Touch sensor 3 comfort. Operating modes: comfort, stand-by, night and frost or heat protection, each with their own temperature setpoints (for heating and/or cooling). Operating modes individually adaptable. A heating timer as a weekly timer with 28 switching times. Room temperature controller extension for controlling air conditioning systems (fan coil) in connection with a KNX gateway for air conditioning systems. Features as a video home station: Camera switching: specific selection of the connected color cameras. Control of the door opener. Turn the ringer on and off. Ring tone selectable from 10 melodies. Properties as a home station with SIP client: Client function for third-party SIP systems from e.g. B. Comelit, TCS, SCHÜCO SIP direct calls or possible via registrar 64 internal calls possible e.g. B. to the Concierge Early Media Support for video image Integration of Internet services: Gira weather portal: Display of the weather forecast for up to five locations (Internet connection required). The Gira G1 can also be used as a client for the following server systems: HomeServer Client eNet Client X1 Client Security system Alarm Connect In the function as a client, the functions of the KNX room operating device are not available. For the precise range of functions, please refer to the Gira online catalog and the technical device documentation. Gira G1 with flush-mounted connection module 24 V WLAN for connection to a suitable cable (e.g. to the second pair of wires of the KNX bus cable). Data communication via WLAN. Notes: Only suitable for indoor use. Recommended mounting height: 150 cm from the floor. It is installed on a deep device socket (recommendation electronics socket for LAN connection). The communication to the KNX installation takes place exclusively via the KNXnet IP standard. A KNX IP router must be used to connect the Gira G1 PoE to the KNX installation. Several Gira G1 can be operated on one KNX IP router. To connect the Gira G1 230 V or G1 24 V to the KNX installation, a Gira KNX IP router (from firmware version 3) is required to ensure reliable communication in the WLAN. For this purpose, the Gira KNX IP router (from firmware version 3) is specially equipped with the additional function reliable data communication. Several Gira G1 can be operated on one Gira KNX IP router (from firmware version 3). Hardware from index status I08 prepared for KNX Secure (additional firmware update required). Commissioning in the KNX system from ETS 5.5 or higher. Can be used as a home station in connection with DCS IP gateway. When planning the system, please note the technical information on network planning in the device documentation. The Gira Project Assistant (GPA) is required for firmware updates. The GPA is available free of charge in the Gira download area. To use the timers, either an Internet connection to an NTP time server or a corresponding KNX timer (e.g. Gira weather station Plus 2074 00) is required. The use of an electronics box is recommended for installing the flush-mounted PoE connection module. A commercially available PoE-capable switch or router or a PoE injector is required. When dimensioning the power supply, it is essential to take into account the total power consumption of all connected loads and the voltage drop across the line network.
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems eNet
Mounting Flush
With display yes
Status LED yes
IR sensor no
Presence button no
With temperature controller yes
With integrated DCF77 receiver no
With timer no
With theft / disassembly protection yes
Central functional unit for transmitters / actuators yes
Material other
Material quality other
Surface protection other
Colour white
Transparent no
IP protection) IP21
With bus coupling no
Min. depth of the device socket 32 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "KNX room control unit, G1, 24V, white 207712"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.