Safety switch 3-p 15kW P1-32/M4/SVB

Eaton - P1-32/M4/SVB - Safety switch 3-p 15kW P1-32/M4/SVB
Photo source: fig. possibly similar
Photo source: fig. possibly similar
P1-32/M4/SVB 172865 4015081694457 EAN/GTIN

$50.96 excl. VAT

14-15 days* (USA)

Safety switch 3-p 15kW, Version as main switch yes, Version as maintenance/repair switch yes,... more
Safety switch 3-p 15kW P1-32/M4/SVB – Eaton – 172865 – 4015081694457: Safety switch 3-p 15kW, Version as main switch yes, Version as maintenance/repair switch yes, Version as safety switch no, Version as emergency stop device yes, Version as reversing switch no, Number of switches 1, Max. rated operating voltage Ue for AC 690V, Rated operating voltage 690V, Rated continuous current Iu 32 A, Rated uninterrupted current at AC-23, 400 V 32 A, Rated continuous current for AC-21, 400 V 32 A, Rated operational power for AC-3, 400V 13 kW, Rated short-time withstand current Icw 0.64 kA, Rated operational power for AC-23, 400V 15 kW, Switching capacity at 400 V 15 kW, Conditional rated short-circuit current Iq 80 kA, Number of poles 3, Motor drive optional no, Motor drive integrated no, Shunt release optional no, Device construction Built-in device fixed-mounted design, Suitable for ground mounting yes, Suitable for front mounting 4-hole no, Suitable for front mounting central no, Suitable for distributor installation no, Suitable for intermediate construction yes, Color of the actuating element red, Lockable yes, Connection type main circuit Screw, Degree of protection (IP), front side IP65, Protection class (NEMA) other
... more
Version as main switch yes
Version as maintenance/repair switch yes
Version as safety switch no
Version as emergency stop device yes
Version as reversing switch no
Number of switches 1
Max. rated operating voltage Ue for AC 690V
Rated operating voltage 690V
Rated continuous current Iu 32 A
Rated uninterrupted current at AC-23, 400 V 32 A
Rated continuous current for AC-21, 400 V 32 A
Rated operational power for AC-3, 400V 13 kW
Rated short-time withstand current Icw 0.64 kA
Rated operational power for AC-23, 400V 15 kW
Switching capacity at 400 V 15 kW
Conditional rated short-circuit current Iq 80 kA
Number of poles 3
Motor drive optional no
Motor drive integrated no
Shunt release optional no
Device construction Built-in device fixed-mounted design
Suitable for ground mounting yes
Suitable for front mounting 4-hole no
Suitable for front mounting central no
Suitable for distributor installation no
Suitable for intermediate construction yes
Color of the actuating element red
Lockable yes
Connection type main circuit Screw
Degree of protection (IP), front side IP65
Protection class (NEMA) other