RCD switch - Residual current breaker 4-p DFS4 080-4/0,03-B SK

Doepke - DFS4 080-4/0,03-B SK - RCD switch - Residual current breaker 4-p DFS4 080-4/0,03-B SK
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DFS4 080-4/0,03-B SK 09154998 4014712148703 EAN/GTIN DE 85624250 WEEE

Our best price
$767.78 excl. VAT
$1,530.65 (-49.84% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Residual current breaker 4-p, Number of poles 4, Rated voltage 400V, Rated current 80 A, Rated... more
RCD switch - Residual current breaker 4-p DFS4 080-4/0,03-B SK – Doepke – 09154998 – 4014712148703: Residual current breaker 4-p, Number of poles 4, Rated voltage 400V, Rated current 80 A, Rated fault current 30 mA, Rated insulation voltage Ui 400V, Rated impulse withstand voltage Uimp 4 kV, Mounting DIN rail, Residual current type B, Selective type no, Short-time delayed type yes, Short-circuit strength (Icw) 10 kA, Surge current resistance 3 kA, Frequency 50 Hz, Additional equipment possible yes, With locking device no, Degree of protection (IP) IP20, Width in modular spacings 4, Installation depth 69 mm, Pollution degree 2
... more
Number of poles 4
Rated voltage 400V
Rated current 80 A
Rated fault current 0.03 A
Rated insulation voltage Ui 400V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type B
Selective type no
Short time delayed type yes
Short-circuit strength (Icw) 10 kA
Surge current resistance 3 kA
Voltage AC
With locking device yes
Frequency 50 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 4
Depth 69 mm
Pollution degree 2
Explosion protection no