Residual current circuit breaker and miniature circuit breaker combination as fire protection swi...

DAFDD 1 B16/0,03/2-A 09961302 4014712235809 EAN/GTIN DE 85624250 WEEE

Our best price
$122.95 excl. VAT
$238.58 (-48.47% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI/LS combination as fire protection. DAFDD 1 B16/0,03/2-A number of poles 2, rated voltage 240V,... more
Residual current circuit breaker and miniature circuit breaker combination as fire protection swi... – Doepke – 09961302 – 4014712235809: FI/LS combination as fire protection. DAFDD 1 B16/0,03/2-A number of poles 2, rated voltage 240V, rated current 16A, rated residual current 0.03A, residual current type A, energy limitation class 3, rated breaking capacity according to EN 61009 10kA, frequency 50Hz, tripping characteristic B, overvoltage category 3, degree of pollution 2 , width in modular units 3, installation depth 70mm, additional devices installed at the factory AFD unit, rated switching current for additional device 16A, rated voltage for additional device 240V, type of control voltage for additional device AC, degree of protection (IP) IP20, AFD unit, arc fault protection devices (AFDD), reduce the risk of fire due to defects in the electrical installation. When serial and parallel arcing faults occur, they switch off the affected part of the system. According to DIN VDE 0100-420, arc fault detection devices are recommended for rooms with sleeping accommodation, rooms and places with a particular risk of fire, rooms and places made of components with combustible building materials, and rooms and places where irreplaceable goods are at risk. DAFDD 1 compactly combine arcing fault detection with line and residual current protection. Contact position displays and the residual current tripped display provide a quick overview. The RCBO part offers protection against type A fault currents, short circuits and overloads, independent of the mains voltage. Switches with tripping characteristic B are the standard protection for light and socket circuits. The standard version is optimized for monitoring circuits with a rated voltage of 230 V and a rated frequency of 50 Hz. Properties: Combination device with three functions, two-pole, variable neutral conductor position, AFDD according to IEC/EN-62606, RCBO according to IEC/EN-61009, continuous self-monitoring of the AFD unit, mains voltage-independent tripping of the RCBO and LS functions, display of AFDD tripping reason, Contact position indicator, residual current tripped indicator, compact size for all rated currents, high short-circuit strength, clamping yoke terminals with rear protection, tristable locking slides for easy installation and removal, type of installation: quick attachment to DIN rail, installation position any, feed from below, areas of application: protection of circuits in residential and commercial buildings as well Industrial plants with TN-S and TN-CS networks. Use in systems with TN-C networks and to protect circuits is excluded. in which power electronics equipment can cause smooth DC fault currents or fault currents with frequencies not equal to 50 Hz.
... more
Number of poles 2
Rated voltage 240V
Rated current 16 A
Rated fault current 0,02999999 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor no
Overvoltage category 3
Pollution degree 2
Width in division units 3
Depth 70 mm
Rated switching current additional device 16 A
Rated voltage additional device 240V
Control voltage type option AC
IP protection) IP20