Main circuit breaker with rail adapter - Selective mains circuit breaker 3-p 50A S751/3-E50

S751/3-E50 2CDS781001R4502 4016779660471 EAN/GTIN DE 91945327 WEEE

Our best price
$90.22 excl. VAT
$430.10 (-79.02% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Main circuit breaker with rail adapter S751/3-E50 Tripping characteristic E, number of poles 3,... more
Main circuit breaker with rail adapter - Selective mains circuit breaker 3-p 50A S751/3-E50 – ABB – 2CDS781001R4502 – 4016779660471: Main circuit breaker with rail adapter S751/3-E50 Tripping characteristic E, number of poles 3, rated current 50A, rated voltage 400V, rated insulation voltage Ui 690V, rated breaking capacity 25kA, frequency 50Hz, overvoltage category 4, degree of pollution 3, rated impulse withstand voltage 6kV, size (according to DIN 43880) 6, type of mounting DIN rail, degree of protection (IP) IP40, the selective main circuit breakers of the S750 series are certified according to DIN VDE 0641-21 as voltage-independent selective main circuit breakers (SHU) and can be operated by laypersons and are designed for the highest overvoltage category. Their area of application is diverse: as a disconnecting device at the meter station in accordance with the TAB of the network operators or VDE-AR-N 4101 as well as in all low-voltage main distribution boards to protect distribution circuits and as an isolating device with a disconnecting function. The special selectivity properties to ensure high system availability should be emphasized. The S750 series is intended for direct mounting on a 4-pole or 5-pole busbar system 40mm (12mm x 5/10mm). Regardless of the rated current of the S750, up to 50mm² and max. 100A can be fed directly to the busbar system via the lower terminal. Devices of the S 750 family include an integrated blocking option that enables the 3 poles of a three-phase supply to be blocked at the same time. The integrated locking slide locks in the ON or OFF position and can also be secured with a padlock, wire seal or cable tie.
... more
Release characteristic other
Number of poles 3
Rated current 50 A
Rated voltage 400V
Rated insulation voltage Ui 690V
Bemessungsabschaltvermögen 25 kA
Coupling neutral conductor no
Frequency 50 Hz
Overvoltage category 4
Pollution degree 3
Rated impulse withstand voltage 6 kV
Mounting Bus bar
IP protection) IP20
Size (according to DIN 43880) 6

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Main circuit breaker with rail adapter - Selective mains circuit breaker 3-p 50A S751/3-E50"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.