AFD unit +FI/LS B10/0.03, 6kA, 3TE - Earth leakage circuit breaker with DS-ARC1 B10 A30

ABB - DS-ARC1 B10 A30 - AFD unit +FI/LS B10/0.03, 6kA, 3TE - Earth leakage circuit breaker with DS-ARC1 B10 A30
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DS-ARC1 B10 A30 2CSA255103R1105 8012542735618 EAN/GTIN DE 91945327 WEEE

Our best price
$216.52 excl. VAT
$353.22 (-38.7% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
AFD unit +FI/LS B10/0.03, 6kA, 3TE DS-ARC1 B10 A30 number of poles 2, rated voltage 230V, rated... more
AFD unit +FI/LS B10/0.03, 6kA, 3TE - Earth leakage circuit breaker with DS-ARC1 B10 A30 – ABB – 2CSA255103R1105 – 8012542735618: AFD unit +FI/LS B10/0.03, 6kA, 3TE DS-ARC1 B10 A30 number of poles 2, rated voltage 230V, rated current 10A, rated residual current 0A, residual current type A, energy limitation class 3, rated breaking capacity according to EN 61009 6kA, rated breaking capacity according to IEC 60947- 2 7.5kA, frequency 50Hz, tripping characteristic B, switching neutral conductor, overvoltage category 3, degree of pollution 2, width in modular widths 3, installation depth 69mm, additional devices factory-fitted AFD unit, rated switching current additional device 10A, rated voltage additional device 230V, control voltage type additional device AC, degree of protection (IP) IP2X , Arc fault protection device (AFDD) with RCBO (RCBO) to IEC/EN 62606 (VDE 0665-10) and IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 ( VDE 0664-21) provide protection against serial and parallel arcing faults, protection against overcurrent (overload or short circuit), protection against sinusoidal alternating currents and pulsating Currents with a smooth DC residual current of up to 6 mA to ground. As well as fault protection (protection against indirect contact) and additional protection (with I?n = 30 mA). Protection against overvoltage (only for AFDD internal) and protection against electrically ignited fires according to DIN VDE 0100-420. Mandatory areas of application according to DIN VDE 0100-420 are in single-phase AC voltage systems with In = 16 A in bedrooms or lounges in homes and day care centers for children, disabled or old people or in barrier-free apartments as well as in rooms or places with a risk of fire (with a special fire risk , fire-endangered business premises), predominantly/mainly made of combustible building materials (classification of the combustibility of the building materials is the responsibility of the manufacturer of the wooden house, for example), endangerment of irreplaceable goods - cultural goods with a particularly high value and in single-phase final circuits that supply electrical equipment in the areas mentioned or traverse these areas. The use of AFDDs is recommended in rooms with sleeping facilities, rooms or locations with fire-spreading structures and final circuits with a high connected load. In general, the AFDD is also recommended to increase fire protection against electrically ignited fires. LED indicator to identify the cause of the trip. Feed-in from above or below, cross-wiring, for example, to an earth leakage circuit breaker in the rear terminal area is possible. System pro M compact® accessories can be attached. Rated switching capacity according to IEC/EN 61009 Icn=6kA. AFDD+RCBO DS-ARC1 is 1-pole protected (LS), 2-pole switching.
... more
Number of poles 2
Rated voltage 230V
Rated current 10 A
Rated fault current 0,02999999 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 6 kA
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
Overvoltage category 3
Pollution degree 2
Width in division units 3
Depth 69 mm
Rated switching current additional device 10 A
Rated voltage additional device 230V
Control voltage type option AC
IP protection) IP40