Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303
750-303
4045454659431
EAN/GTIN
DE 40917098
WEEE
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Fieldbus coupler DP/FMS 12 MBD 750-303 With integrated power supply, input voltage at DC...
more
Fieldbus coupler DP/FMS 12 MBD - Fieldbus basic device DC24V 750-303 – WAGO – 4045454659431: Fieldbus coupler DP/FMS 12 MBD 750-303 With integrated power supply, input voltage at DC 24...24V, type of input voltage DC, max. input current at DC 0.5A, number of HW interfaces Industrial Ethernet 0, number of interfaces PROFINET 0 , Number of HW interfaces serial RS-232 0, Number of HW interfaces serial RS-422 0, Number of HW interfaces serial RS-485 1, Number of HW interfaces serial TTY 0, Number of HW interfaces USB 0 , Number of HW interfaces in parallel 0, Number of HW interfaces wireless 0, Number of HW interfaces other 0, Supports protocol for PROFIBUS, System component, degree of protection (IP) IP20, Number of slots 1, With plug-in modules, digital E/ A, with pluggable assemblies, analog I/O, with pluggable assemblies, communication modules, with pluggable assemblies, function and technology modules, with pluggable assemblies, central modules, with pluggable assemblies, other, execution of the electrical Spring-loaded connection, With electrical isolation, With bus coupler for modular station structure, DIN rail mounting possible, Explosion protection category for gas ATEX gas explosion protection, Cat. 3G, Explosion protection category for dust ATEX dust explosion protection, Cat. 3D, width 51mm, Height 65mm, depth 100mm This fieldbus coupler connects the WAGO-I/O-SYSTEM as a slave to the PROFIBUS fieldbus. The bus coupler recognizes all plugged-in I/O terminals and uses them to create a local process image. This can involve a mixed arrangement of analog (data exchange word by word) and digital (data exchange bit by bit) terminals. The image is displayed in the memory of the responsible controller via the PROFIBUS fieldbus. The local process image is divided into an input and an output data area. The process data can be read in via the PROFIBUS and further processed in a controller. The process output data are output via the PROFIBUS. The data from the analog terminals are stored in the automatically created process image in the order of their position after the bus coupler. The bits of the digital terminals are combined into bytes and appended to the analog data. If the number of digital I/Os is greater than 8 bits, the coupler automatically starts another byte. For new installations with PROFIBUS DP, consider the fieldbus coupler 750-333 with extended functions. Caution: Configuration files (GSD) required!
...
more
With integrated power supply | yes |
Input voltage at DC | 24V |
Type of input voltage | DC |
Max. Input current at DC | 0.5 A |
Number of HW interfaces serial RS-485 | 1 |
With optical interface | no |
Supports protocol for TCP / IP | no |
Supports protocol for PROFIBUS | yes |
Supports protocol for CAN | no |
Supports protocol for INTERBUS | no |
Supports protocol for ASI | no |
Supports protocol for KNX | no |
Supports protocol for MODBUS | no |
Supports data highway protocol | no |
Supports protocol for DeviceNet | no |
Supports protocol for SUCONET | no |
Supports protocol for LON | no |
Supports protocol for SERCOS | no |
Supports protocol for PROFINET IO | no |
Supports protocol for PROFINET CBA | no |
Supports protocol for EtherNet / IP | no |
Supports protocol for DeviceNet Safety | no |
Supports protocol for INTERBUS safety | no |
Supports protocol for PROFIsafe | no |
Supports protocol for SafetyBUS p | no |
Wireless standard Bluetooth | no |
Wireless standard WLAN 802.11 | no |
Radio standard GPRS | no |
Radio standard GSM | no |
Radio standard UMTS | no |
IO-Link master | no |
System component | yes |
IP protection) | IP20 |
Number of slots | 1 |
With pluggable assemblies, digital I / O | yes |
With plug-in modules, analog I / O | yes |
With plug-in modules, communication modules | yes |
With pluggable modules, central modules | yes |
With pluggable modules, miscellaneous | yes |
With electrical isolation | yes |
With bus coupler for modular station design | yes |
Rail mounting possible | yes |
Wall / direct mounting possible | no |
Front installation possible | no |
Rack mounting possible | no |
Suitable for safety functions | no |
Associated equipment (Ex ia) | no |
Associated equipment (Ex ib) | no |
Width | 50.5 mm |
Height | 100 mm |
Depth | 71.1 mm |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Google analytics
Partner program
Custom tracking