Analog input terminal 2-channel, XTR - Fieldbus analogue module 2 In / 0 Out 750-482
750-482
4017332319522
EAN/GTIN
DE 40917098
WEEE
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Analog input terminal 2-channel, XTR 750-482 supply voltage at DC 24... 24V, voltage type of the...
more
Analog input terminal 2-channel, XTR - Fieldbus analogue module 2 In / 0 Out 750-482 – WAGO – 4017332319522: Analog input terminal 2-channel, XTR 750-482 supply voltage at DC 24... 24V, voltage type of the supply voltage DC, input, voltage, resolution of the analog inputs 12-bit, number of analog inputs 2, number of analog outputs 0, number of HW interfaces Industrial Ethernet 0, number of PROFINET interfaces 0, number of HW interfaces serial RS-232 0, number of HW interfaces serial RS-422 0, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0 , number of parallel HW interfaces 0, number of wireless HW interfaces 0, number of USB HW interfaces 0, number of other HW interfaces 0, system components, degree of protection (IP) IP20, design of the electrical connection spring-loaded connection, fieldbus connection via separate bus coupler possible, DIN rail mounting possible, explosion protection category for gas without, explosion protection category for dust without, width 12mm, height 64mm, depth 100mm, the analog input terminal h at the task of supplying the measuring transducers located in the field and transmitting analogue measuring signals to the bus system in a galvanically isolated manner. The supply voltage of 24 V is fed in via the power contacts for the field. The shield connection is routed directly to the mounting rail. The overload protection switches the measuring input to the high-impedance state from a current of approx. 25 mA. The high-impedance state is automatically reset when returning to the normal measuring range. This terminal provides the power supply for 2-wire transmitters that do not have their own power supply. Up to 4 HART secondary variables (PV, SV, TV, QV) can be displayed in the cyclic process image of the coupler or controller per channel (configurable). For HART communication to connected intelligent HART field devices, the HART protocol can be displayed in the cyclic process image of the coupler or controller (configurable). FDT/DTM device drivers are available for some (programmable) couplers, with which HART tool routing to the connected HART device is possible.
...
more
Supply voltage at DC | 24V |
Voltage type of the supply voltage | DC |
Entrance, electricity | no |
Input, voltage | yes |
Entrance, resistance | no |
Entrance, resistance thermometer | no |
Input, thermocouple | no |
Input signal configurable | no |
Resolution of the analog inputs | 12 bits |
Output, electricity | no |
Output, voltage | no |
Output signal configurable | no |
Number of analog inputs | 2 |
Analog inputs configurable | no |
Analog outputs configurable | no |
Supports protocol for TCP / IP | no |
Supports protocol for PROFIBUS | no |
Supports protocol for CAN | no |
Supports protocol for INTERBUS | no |
Supports protocol for ASI | no |
Supports protocol for KNX | no |
Supports protocol for MODBUS | no |
Supports data highway protocol | no |
Supports protocol for DeviceNet | no |
Supports protocol for SUCONET | no |
Supports protocol for LON | no |
Supports protocol for PROFINET IO | no |
Supports protocol for PROFINET CBA | no |
Supports protocol for SERCOS | no |
Supports protocol for EtherNet / IP | no |
Supports protocol for DeviceNet Safety | no |
Supports protocol for INTERBUS safety | no |
Supports protocol for PROFIsafe | no |
Supports protocol for SafetyBUS p | no |
Wireless standard Bluetooth | no |
Wireless standard WLAN 802.11 | no |
Radio standard GPRS | no |
Radio standard GSM | no |
Radio standard UMTS | no |
IO-Link master | no |
System component | yes |
IP protection) | IP20 |
Rail mounting possible | yes |
Wall / direct mounting possible | no |
Front installation possible | no |
Rack mounting possible | no |
Suitable for safety functions | no |
Associated equipment (Ex ia) | no |
Associated equipment (Ex ib) | no |
Width | 12 mm |
Height | 100 mm |
Depth | 69.8 mm |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Google analytics
Partner program
Custom tracking