Analog input terminal 2-channel, XTR - Fieldbus analogue module 2 In / 0 Out 750-482

WAGO - 750-482 - Analog input terminal 2-channel, XTR - Fieldbus analogue module 2 In / 0 Out 750-482
Photo source: fig. possibly similar
Photo source: fig. possibly similar
750-482 4017332319522 EAN/GTIN DE 40917098 WEEE

Our best price
$485.08 excl. VAT

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Analog input terminal 2-channel, XTR 750-482 supply voltage at DC 24... 24V, voltage type of the... more
Analog input terminal 2-channel, XTR - Fieldbus analogue module 2 In / 0 Out 750-482 – WAGO – 4017332319522: Analog input terminal 2-channel, XTR 750-482 supply voltage at DC 24... 24V, voltage type of the supply voltage DC, input, voltage, resolution of the analog inputs 12-bit, number of analog inputs 2, number of analog outputs 0, number of HW interfaces Industrial Ethernet 0, number of PROFINET interfaces 0, number of HW interfaces serial RS-232 0, number of HW interfaces serial RS-422 0, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0 , number of parallel HW interfaces 0, number of wireless HW interfaces 0, number of USB HW interfaces 0, number of other HW interfaces 0, system components, degree of protection (IP) IP20, design of the electrical connection spring-loaded connection, fieldbus connection via separate bus coupler possible, DIN rail mounting possible, explosion protection category for gas without, explosion protection category for dust without, width 12mm, height 64mm, depth 100mm, the analog input terminal h at the task of supplying the measuring transducers located in the field and transmitting analogue measuring signals to the bus system in a galvanically isolated manner. The supply voltage of 24 V is fed in via the power contacts for the field. The shield connection is routed directly to the mounting rail. The overload protection switches the measuring input to the high-impedance state from a current of approx. 25 mA. The high-impedance state is automatically reset when returning to the normal measuring range. This terminal provides the power supply for 2-wire transmitters that do not have their own power supply. Up to 4 HART secondary variables (PV, SV, TV, QV) can be displayed in the cyclic process image of the coupler or controller per channel (configurable). For HART communication to connected intelligent HART field devices, the HART protocol can be displayed in the cyclic process image of the coupler or controller (configurable). FDT/DTM device drivers are available for some (programmable) couplers, with which HART tool routing to the connected HART device is possible.
... more
Supply voltage at DC 24V
Voltage type of the supply voltage DC
Entrance, electricity no
Input, voltage yes
Entrance, resistance no
Entrance, resistance thermometer no
Input, thermocouple no
Input signal configurable no
Resolution of the analog inputs 12 bits
Output, electricity no
Output, voltage no
Output signal configurable no
Number of analog inputs 2
Analog inputs configurable no
Analog outputs configurable no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
IP protection) IP20
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Width 12 mm
Height 100 mm
Depth 69.8 mm