Monitoring relay anal. - Level relay 3UG4501-2AA30

Siemens - 3UG4501-2AA30 - Monitoring relay anal. - Level relay 3UG4501-2AA30
Photo source: fig. possibly similar
Photo source: fig. possibly similar
3UG4501-2AA30 4011209665316 EAN/GTIN DE 23691322 WEEE

$83.08 excl. VAT
$150.51 (-44.8% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Type of electric connection=Spring clamp connection, Rated control supply voltage Us at AC... more
Monitoring relay anal. - Level relay 3UG4501-2AA30 – Siemens – 4011209665316: Type of electric connection=Spring clamp connection, Rated control supply voltage Us at AC 50HZ=24 V, Rated control supply voltage Us at AC 60HZ=24 V, Rated control supply voltage Us at DC=24 V, Voltage type for actuating=AC/DC, With detachable clamps=yes, Number of inputs for electrodes=1, Min. adjustable operate delay time=0,5 s, Max. permitted operate delay time=10 s, Min. adjustable off-delay time=0,5 s, Max. permitted off-delay time=10 s, Response value sensitivity adjustable=yes, Number of contacts as change-over contact=1, Physical measurement principle=Other, Width=22,5 mm, Height=94 mm, Depth=91 mm
... more
Rated control supply voltage Us at DC 24V
Voltage type for actuation AC/DC
With removable clamps yes
Number of electrode inputs 1
Minimum adjustable pick-up delay time 0.5 s
Max. Permissible pick-up delay time 10 s
Max. Allowable fallback delay time 10 s
Sensitivity adjustable yes
Number of contacts as changer 1
Physical measuring principle other
Width 22.5 mm
Height 94 mm
Depth 91 mm