Surge arresters - Surge protection device 230V 2-pole BT-1S-230AC/A

Phoenix - BT-1S-230AC/A - Surge arresters - Surge protection device 230V 2-pole BT-1S-230AC/A
Photo source: fig. possibly similar
Photo source: fig. possibly similar
BT-1S-230AC/A 2803409 4046356350976 EAN/GTIN DE 50738265 WEEE

Our best price
$50.35 excl. VAT
$93.71 (-46.27% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Surge arrester BT-1S-230AC/A Other mounting type, rated voltage AC 230V, maximum continuous... more
Surge arresters - Surge protection device 230V 2-pole BT-1S-230AC/A – Phoenix – 2803409 – 4046356350976: Surge arrester BT-1S-230AC/A Other mounting type, rated voltage AC 230V, maximum continuous voltage AC 275V, rated load current 16A, rated discharge current (8/20) (LN) 3kA, total discharge current (8/20) (L+N-PE) 3kA, protection level 1.3kV, protection level LN 1.3kV, protection level L-PE/N-PE 1.5kV, number of poles 2, acoustic signaling on the device, max. conductor cross-section solid (solid/stranded) 2.5mm², max. conductor cross-section flexible (finely stranded ) 2.5mm², test class type 3, type 3 arrester for universal installation in installation boxes, wall ducts, underfloor installations or directly in the end device. Circuit thermally monitored, acoustic error message. Installation in branch or through wiring. Version: 230 V AC
... more
Rated voltage AC 230V
Highest continuous voltage AC 275 V
Nominal load current 16 A
Nominal discharge current (8/20) (LN) 3 kA
Total discharge current (8/20) (L + N-PE) 3 kA
Protection level 1.3 kV
Protection level LN 1.3 kV
Protection level L-PE / N-PE 1.5 kV
Number of poles 2
Mounting screwable
With telecommunication contact no
Signaling on the device acoustically
Test class type 3 yes
With noise filter no