Isolating spark gap for hazardous areas - Spark gap for lighting protection EXFS KU

Dehn - EXFS KU - Isolating spark gap for hazardous areas - Spark gap for lighting protection EXFS KU
Photo source: fig. possibly similar
Photo source: fig. possibly similar
EXFS KU 923019 4013364033177 EAN/GTIN DE 11890845 WEEE

$340.82 excl. VAT
$679.47 (-49.84% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Isolating spark gap f.Ex area EXFS KU lightning impulse current (10/350 µs) 50kA, rated response... more
Isolating spark gap for hazardous areas - Spark gap for lighting protection EXFS KU – Dehn – 923019 – 4013364033177: Isolating spark gap f.Ex area EXFS KU lightning impulse current (10/350 µs) 50kA, rated response impulse voltage 2.5kV, rated alternating current withstand voltage 300V, connection flange, suitable for other connections, material of the connection stainless steel (V2A), explosion-tested version, protection class (IP) IP67, isolating spark gaps for the Ex area for indirect connection/grounding of operationally separate system parts in the event of lightning. For safe use in explosion protection zone 2 (gases). ATEX-certified isolating spark gap for lightning protection equipotential bonding according to DIN EN 62305 / VDE 0185 in a proven design with flexible conductor connection.
... more
Lightning impulse current (10/350 µs) 50 kA
Measuring impulse sparkover voltage 2.5 kV
Measuring power frequency withstand voltage 300V
Connection Flange
Suitable for connection other
Material of the connection Stainless steel (V2A)
Explosion-tested version yes
IP protection) IP67