Voltage monitoring relay 0...540V AC CM-UFD.M31

CM-UFD.M31 1SVR560730R3401 4013614492914 EAN/GTIN DE 91945327 WEEE

Our best price
$461.25 excl. VAT
$883.61 (-47.8% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Monitoring relay CM-UFD.M31 Rated control supply voltage Us at AC 50 Hz 24 ... 240V, Rated... more
Voltage monitoring relay 0...540V AC CM-UFD.M31 – ABB – 1SVR560730R3401 – 4013614492914: Monitoring relay CM-UFD.M31 Rated control supply voltage Us at AC 50 Hz 24 ... 240V, Rated control supply voltage Us at AC 60 Hz 24 ... 240V, Rated control supply voltage Us at DC 24 ... 240V, Undervoltage detection function, Overvoltage detection function, voltage measuring range 0 .. 540V, number of contacts as opener 0, number of contacts as closer 0, number of contacts as changer 3, width 108mm, height 90mm, depth 67mm, The grid feed monitoring relay CM-UFD.M31 monitors voltage and frequency in single and three-phase grids. In connection with inverters with integrated island grid detection, it meets the conditions for NS protection according to VDE-AR-N 4105:2018-11 (generating systems on the low-voltage grid), or VDE-AR-N 4110:2018-11 ((generating systems on the medium-voltage grid ). For use in old systems, the setting values according to VDE-AR-N 4105:2011 or BDEW (supply to medium-voltage network) can also be selected. The last 99 causes of switch-off and their respective times are stored in an alarm memory Monitoring of the connected tie switches, vector surge detection and ROCOF frequency gradient monitoring.
... more
With removable clamps no
1-phase undervoltage possible yes
3-phase undervoltage possible yes
1-phase overvoltage possible yes
3-phase overvoltage possible yes
1-phase window possible yes
3-phase window possible yes
Contains function DC voltage window no
Voltage measuring range 1 0..540 V
Voltage type of the measuring range AC
Voltage type for actuation AC/DC
Pickup voltage 0..540 V
Minimum adjustable response delay time 0 s
Max. Allowable response delay time 0 s
Minimum adjustable fallback delay time 0 s
Max. Allowable fallback delay time 0 s
Number of contacts as changer 3
Width 108 mm
Height 90 mm
Depth 67 mm