Fieldbus coupler ethernet TCP/IP - Fieldbus basic device DC24V 750-342

WAGO - 750-342 - Fieldbus coupler ethernet TCP/IP - Fieldbus basic device DC24V 750-342
Photo source: fig. possibly similar
Photo source: fig. possibly similar
750-342 4045454527006 EAN/GTIN DE 40917098 WEEE

Our best price
$462.20 excl. VAT

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
With integrated power supply=no, Input voltage at DC=24 V, Type of voltage (input voltage)=DC,... more
Fieldbus coupler ethernet TCP/IP - Fieldbus basic device DC24V 750-342 – WAGO – 4045454527006: With integrated power supply=no, Input voltage at DC=24 V, Type of voltage (input voltage)=DC, Max. input current DC=0,5 A, Number of HW-interfaces industrial Ethernet=1, With optical interface=no, Supporting protocol for TCP/IP=no, Supporting protocol for PROFIBUS=no, Supporting protocol for CAN=no, Supporting protocol for INTERBUS=no, Supporting protocol for ASI=no, Supporting protocol for KNX=no, Supporting protocol for MODBUS=yes, Supporting protocol for Data-Highway=no, Supporting protocol for DeviceNet=no, Supporting protocol for SUCONET=no, Supporting protocol for LON=no, Supporting protocol for SERCOS=no, Supporting protocol for PROFINET IO=no, Supporting protocol for PROFINET CBA=no, Supporting protocol for Foundation Fieldbus=no, Supporting protocol for EtherNet/IP=yes, Supporting protocol for AS-Interface Safety at Work=no, Supporting protocol for DeviceNet Safety=no, Supporting protocol for INTERBUS-Safety=no, Supporting protocol for PROFIsafe=no, Supporting protocol for SafetyBUS p=no, Supporting protocol for other bus systems=yes, Radio standard Bluetooth=no, Radio standard Wi-Fi 802.11=no, Radio standard GPRS=no, Radio standard GSM=no, Radio standard UMTS=no, IO link master=no, System accessory=yes, Degree of protection (IP)=IP20, Number of slots=1, With pluggable modules, digital I/O=yes, With pluggable modules, analogue I/O=yes, With pluggable modules, communication modules=yes, With pluggable modules, function and technology modules=yes, With pluggable modules, central modules=yes, With pluggable modules, others=yes, Type of electric connection=Spring clamp connection, With potential separation=yes, Fieldbus connection over separate bus coupler possible=no, With bus coupler for modular station connection=yes, Rail mounting possible=yes, Wall mounting/direct mounting=no, Front built-in possible=no, Rack-assembly possible=no, Suitable for safety functions=no, Appendant operation agent (Ex ia)=no, Appendant operation agent (Ex ib)=no, Explosion safety category for gas=ATEX gas-ex-protection, Cat. 3G, Explosion safety category for dust=ATEX dust-ex-protection, Cat. 3D, Width=51 mm, Height=65 mm, Depth=100 mm
... more
With integrated power supply no
Input voltage at DC 24V
Type of input voltage DC
Max. Input current at DC 0.5 A
Number of HW interfaces Industrial Ethernet 1
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS yes
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for SERCOS no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for EtherNet / IP yes
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Wireless standard Bluetooth no
Wireless standard WLAN 802.11 no
Radio standard GPRS no
Radio standard GSM no
Radio standard UMTS no
IO-Link master no
System component yes
IP protection) IP20
Number of slots 1
With pluggable assemblies, digital I / O yes
With plug-in modules, analog I / O yes
With plug-in modules, communication modules yes
With pluggable modules, central modules yes
With pluggable modules, miscellaneous yes
With electrical isolation yes
With bus coupler for modular station design yes
Rail mounting possible yes
Wall / direct mounting possible no
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Width 50.5 mm
Height 100 mm
Depth 71.1 mm