Residual current circuit breaker with line protection B 25A 1+N 30mA 10kA 5SU1354-3KK25

5SU1354-3KK25 4001869460796 EAN/GTIN DE 23691322 WEEE

Our best price
$196.19 excl. VAT
$380.20 (-48.4% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
RCBO type F, 30mA, B25 5SU1354-3KK25 number of poles (total) 2, number of fused poles 1, rated... more
Residual current circuit breaker with line protection B 25A 1+N 30mA 10kA 5SU1354-3KK25 – Siemens – 4001869460796: RCBO type F, 30mA, B25 5SU1354-3KK25 number of poles (total) 2, number of fused poles 1, rated voltage 230V, rated insulation voltage Ui 264V, rated impulse withstand voltage Uimp 4kV, rated current 25A, rated residual current 0.03A, residual current type other, Energy limitation class 3, rated breaking capacity according to EN 61009 10kA, rated breaking capacity according to IEC 60947-2 20kA, rated short-circuit breaking capacity Icn according to EN 61009-1 10kA, switch-off characteristics other, surge current strength 3kA, type of voltage AC, frequency other, tripping characteristic B, switching neutral conductor, with locking device, overvoltage category 3, Pollution degree 2, ambient temperature during operation -25 ... 55°C, width in pitch units 2, installation depth 70mm, suitable for flush-mounted installation, protection against false tripping, protection class (IP) IP20, connectable conductor cross-section solid 0.75 ... 35mm², connectable Conductor cross-section stranded 0.75 ... 35mm², RCBO, 10 kA, 1P+N, type F, super-resistant K, 30 mA, B-Char, In: 25 A, Un AC: 230 V RCBO for combined short-circuit protection and protection against accidental contact. The patented RCBOs from Siemens - as an important component of the SENTRON protective devices for electrical installations, enable combined personal fire and line protection in just one device. In addition to detecting fault currents, they also offer reliable protection against short circuits and overload thanks to the integrated overcurrent protection device. The Siemens RCBOs as a combination of residual current circuit breakers and miniature circuit breakers are characterized above all by: 1. Increased operational reliability and system availability thanks to the separate shutdown of the circuit concerned. 2. Whether sinusoidal AC residual currents or smooth DC residual currents - Siemens offers the right type and special versions for all requirements. 3. Reliable safety during installation thanks to the grip and touch protection included as standard. 4. Tool-free removal from the top-hat rail or from the busbar assembly through convenient slide-hand operation. 5. Clearly visible switch position indicator. 6. Data matrix code on the front of the device provides all information about the RCBO quickly and easily. 7. Be protected according to standards: The RCBOs comply with the provisions of DIN VDE. 8. Optimum technology for your safety - only from Siemens. For the safe, efficient electrical infrastructure in buildings and industry, Siemens offers an integrated portfolio of protective switching, measuring and monitoring devices, distribution systems, switches and socket outlets.
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 230V
Rated insulation voltage Ui 264 V
Rated impulse withstand voltage Uimp 4 kV
Rated current 25 A
Rated fault current 0.03 A
Fault current type other
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic other
Surge current resistance 3 kA
Voltage AC
Frequency 50 Hz
Release characteristic B
Coupling neutral conductor yes
With locking device yes
Overvoltage category 2
Pollution degree 2
Width in division units 2
Depth 70 mm
Flush mounting yes
False triggering protection yes
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Residual current circuit breaker with line protection B 25A 1+N 30mA 10kA 5SU1354-3KK25"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.