Circuit breaker 3VA1 IEC frame 160 3VA1110-5EF32-0KH0

Siemens - 3VA1110-5EF32-0KH0 - Circuit breaker 3VA1 IEC frame 160 3VA1110-5EF32-0KH0
Photo source: fig. possibly similar
Photo source: fig. possibly similar
3VA1110-5EF32-0KH0 4042949092087 EAN/GTIN DE 23691322 WEEE

$498.94 excl. VAT
$788.83 (-36.75% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Circuit-breaker 100A Rated permanent current Iu 100A, Rated voltage 690 ... 690V, Rated... more
Circuit breaker 3VA1 IEC frame 160 3VA1110-5EF32-0KH0 – Siemens – 4042949092087: Circuit-breaker 100A Rated permanent current Iu 100A, Rated voltage 690 ... 690V, Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 55kA, Overload release current setting 70 ... 100A, Adjustment range undelayed short-circuit release 500 ... 1000A, Type of electrical connection of main circuit Screw connection, Device construction Built-in device fixed built-in technique, Suitable for DIN rail (top hat rail) mounting, DIN rail (top hat rail) mounting optional, Number of auxiliary contacts as normally closed contact 0, Number of auxiliary contacts as normally open contact 0, Number of auxiliary contacts as change-over contact 3, With switched-off indicator, Number of poles 3, Position of connection for main current circuit Front side, Type of control element Rocker lever, Complete device with protection unit, Motor drive optional, Degree of protection (IP) IP40
... more
Rated continuous current Iu 100 A
Rated voltage 690V
Overload release Current setting 70..100 A
Connection type main circuit Screw
Device construction Built-in device fixed-mounted design
Suitable for DIN rail mounting yes
DIN rail mounting optional yes
Number of auxiliary contacts as a changeover contact 3
With trip indicator yes
With integrated undervoltage release no
Number of poles 3
Execution of the actuating element Rocker arm
Complete unit with protection unit yes
Motor drive integrated no
Motor drive optional yes
IP protection) IP40