Residual current circuit breaker 4-pole 25A/30mA, QC CDS425D

CDS425D 3250611610854 EAN/GTIN DE 23692311 WEEE

Our best price
$51.08 excl. VAT
$143.92 (-64.51% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI circuit breaker 4-pole 25A/30mA,6kA,QC CDS425D number of poles 4, rated voltage 400V, rated... more
Residual current circuit breaker 4-pole 25A/30mA, QC CDS425D – Hager – 3250611610854: FI circuit breaker 4-pole 25A/30mA,6kA,QC CDS425D number of poles 4, rated voltage 400V, rated current 25A, rated residual current 30mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, mounting type DIN rail, residual current type A, short-circuit strength (Icw) 6kA, surge current strength 0.25kA, frequency 50 Hz, additional equipment possible, degree of protection (IP) IP20, width in pitch units 4, installation depth 70mm, ambient temperature during operation -25 ... 40°C, degree of pollution 2, connectable conductor cross-section stranded 1 ... 16mm², Connectable conductor cross-section solid 1 ... 25mm², residual current circuit breaker 4-pole 6kA 25A 30mA type A QuickConnect. Residual current circuit breaker according to DIN EN 61008-2-1 and VDE 0664 part 10 + 11. QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11 at the entrance up to 63 A, protection against accidental contact IP2x according to DIN VDE 0106 part 100, blue test button and residual current indicator. Easy individual removal from the phase busbar assembly. With VDE mark. Suitable for retrofitting additional equipment. Labeling option directly on the device. Suitable for retrofitting additional equipment.
... more
Number of poles 4
Rated voltage 400V
Rated current 25 A
Rated fault current 0.03 A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 6 kA
Surge current resistance 0.25 kA
Voltage AC
With locking device yes
Frequency 50 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 4
Depth 70 mm
Pollution degree 2
Explosion protection no