Residual current circuit breaker, 4-pole, 25A 300mA type A A9Z24425

A9Z24425 3606480443183 EAN/GTIN DE 33842582 WEEE

Our best price
$45.71 excl. VAT
$132.73 (-65.56% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI switch 4P 25A 300mA type A A9Z24425 number of poles 4, rated voltage 400V, rated current 25A,... more
Residual current circuit breaker, 4-pole, 25A 300mA type A A9Z24425 – Schneider Electric – 3606480443183: FI switch 4P 25A 300mA type A A9Z24425 number of poles 4, rated voltage 400V, rated current 25A, rated residual current 300mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 6kV, mounting type DIN rail, residual current type A, short-circuit strength (Icw) 10kA, surge current strength 0.25kA, Frequency 50/60 Hz, additional equipment possible, with locking device, degree of protection (IP) IP20, width in pitch units 4, installation depth 50mm, ambient temperature during operation 25 ... 60°C, degree of pollution 3, connectable conductor cross-section stranded 1 ... 25mm², Connectable conductor cross-section solid 1 ... 35mm², residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 25A, ground fault sensitivity 300mA, ground fault protection class type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Guarantees additional protection against direct contact (<= 30mA). Fault protection in the event of indirect contact, e.g. in the event of insulation faults (>= 100mA, <= 300mA). Error protection in site power distributors (500mA). Switching and disconnecting circuits. Snap action for low-wear switching of the contacts. With mechanical error message display on the front (VisiTrip) for displaying trips due to overload or short circuit. Safe contact indicator (VisiSafe) of the residual current circuit breaker, green indicator means there is no voltage on the outgoing side. Test button for regular function testing. Double connection terminals for connecting cables or busbars on both sides. Simple removal of the individual device with the phase busbar installed, thanks to the fastening element that can be reached from the front. Additional add-on auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt release (iMX), auxiliary switch for status reporting (iOF), fault signaling switch (iSD). Tool-free assembly on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards - IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
... more
Number of poles 4
Rated voltage 400V
Rated current 25 A
Rated fault current 0.3 A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 6 kV
Mounting DIN rail
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 10 kA
Surge current resistance 0.25 kA
Voltage AC
With locking device yes
Frequency 50/60 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 4
Depth 44 mm
Pollution degree 3
Explosion protection no

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Residual current circuit breaker, 4-pole, 25A 300mA type A A9Z24425"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.