Frequency converter 1.5kW 380-500V with EMC ATV31CU15N4

Schneider Electric - ATV31CU15N4 - Frequency converter 1.5kW 380-500V with EMC ATV31CU15N4
Photo source: fig. possibly similar
ATV31CU15N4 3389110587807 EAN/GTIN

$788.05 excl. VAT
$1,351.70 (-41.7% RRP***)

14-15 days* (USA)

Mains voltage=380..500 V, Mains frequency=50/60 Hz, Number of phases input=3, Number of phases... more
Frequency converter 1.5kW 380-500V with EMC ATV31CU15N4 – Schneider Electric – ATV31CU15N4 – 3389110587807: Mains voltage=380..500 V, Mains frequency=50/60 Hz, Number of phases input=3, Number of phases output=3, Max. output frequency=500 Hz, Max. output voltage=500 V, Nominal output current I2N=4,1 A, Max. output at quadratic load at rated output voltage=1,5 kW, Max. output at linear load at rated output voltage=1,5 kW, Relative symmetric net frequency tolerance=5 %, Relative symmetric net voltage tolerance=10 %, Number of analogue outputs=1, Number of analogue inputs=3, Number of digital outputs=2, Number of digital inputs=6, With control element=yes, Application in industrial area permitted=yes, Application in domestic- and commercial area permitted=yes, Supporting protocol for TCP/IP=no, Supporting protocol for PROFIBUS=yes, Supporting protocol for CAN=yes, Supporting protocol for INTERBUS=no, Supporting protocol for ASI=no, Supporting protocol for KNX=no, Supporting protocol for MODBUS=yes, Supporting protocol for Data-Highway=no, Supporting protocol for DeviceNet=yes, Supporting protocol for SUCONET=no, Supporting protocol for LON=no, Supporting protocol for PROFINET IO=no, Supporting protocol for PROFINET CBA=no, Supporting protocol for SERCOS=no, Supporting protocol for Foundation Fieldbus=no, Supporting protocol for EtherNet/IP=no, Supporting protocol for AS-Interface Safety at Work=no, Supporting protocol for DeviceNet Safety=no, Supporting protocol for INTERBUS-Safety=no, Supporting protocol for PROFIsafe=no, Supporting protocol for SafetyBUS p=no, Supporting protocol for BACnet=no, Supporting protocol for other bus systems=no, Number of HW-interfaces RS-485=1, Number of HW-interfaces other=12, With optical interface=no, With PC connection=yes, Integrated breaking resistance=no, 4-quadrant operation possible=no, Type of converter=U converter, Degree of protection (IP)=IP55, Height=297 mm, Width=215 mm, Depth=192 mm
... more
Mains voltage 380..500V
Power frequency 50/60 Hz
Input phase number 3
Output phase number 3
Max. Output frequency 500 Hz
Max. Output voltage 500V
Rated output current I2N 4.1A
Relative symmetric power frequency tolerance 5%
Relative symmetrical mains voltage tolerance 10%
Number of analog outputs 1
Number of analog inputs 3
Number of digital outputs 2
Number of digital inputs 6
With operating element yes
Use in the industrial sector permitted yes
Use in residential and commercial areas permitted yes
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS yes
Supports protocol for CAN yes
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS yes
Supports data highway protocol no
Supports protocol for DeviceNet yes
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
Supports protocol for BACnet no
Number of HW interfaces serial RS-485 1
Number of HW interfaces other 12
With optical interface no
With PC connection yes
Integrated brake chopper no
4-quadrant operation possible no
Type of inverter Voltage converters
IP protection) IP55
Height 297 mm
Width 215 mm