Direct starter coil 400VAC - Direct starter combination 5,5kW LG7D12V716
LG7D12V716
3389110761085
EAN/GTIN
Type of motor starter Direct starter (DOL), With short-circuit release yes, Voltage type for...
more
Direct starter coil 400VAC - Direct starter combination 5,5kW LG7D12V716 –
Schneider Electric
– LG7D12V716
– 3389110761085:
Type of motor starter Direct starter (DOL), With short-circuit release yes, Voltage type for actuation AC, Rated operating power at AC-3, 400V 5.5 kW, Rated power, 460 V, 60 Hz, 3-phase 5.5 kW, Rated operational current Ie 12 A, Rated operating current at AC-3, 400 V 12 A, Overload release Current setting 9..14 A, Temperature compensated overload protection yes, Trip class CLASS 10, Connection type main circuit Screw, Rail mounting possible no, With transformer no, Number of command points 5, Suitable for EMERGENCY STOP yes, Assignment type according to IEC 60947-4-3 Class 1, External reset possible no, With fuse no, IP protection) IP55, Supports protocol for TCP / IP no, Supports protocol for PROFIBUS no, Supports protocol for CAN no, Supports protocol for INTERBUS no, Supports protocol for ASI no, Supports protocol for MODBUS no, Supports data highway protocol no, Supports protocol for DeviceNet no, Supports protocol for SUCONET no, Supports protocol for LON no, Supports protocol for PROFINET IO no, Supports protocol for PROFINET CBA no, Supports protocol for SERCOS no, Supports protocol for EtherNet / IP no, Supports protocol for DeviceNet Safety no, Supports protocol for INTERBUS safety no, Supports protocol for PROFIsafe no, Supports protocol for SafetyBUS p no, Width 175 mm, Height 165 mm, Depth 177 mm
...
more
Type of motor starter | Direct starter (DOL) |
With short-circuit release | yes |
Voltage type for actuation | AC |
Rated operating power at AC-3, 400V | 5.5 kW |
Rated power, 460 V, 60 Hz, 3-phase | 5.5 kW |
Rated operational current Ie | 12 A |
Rated operating current at AC-3, 400 V | 12 A |
Overload release Current setting | 9..14 A |
Temperature compensated overload protection | yes |
Trip class | CLASS 10 |
Connection type main circuit | Screw |
Rail mounting possible | no |
With transformer | no |
Number of command points | 5 |
Suitable for EMERGENCY STOP | yes |
Assignment type according to IEC 60947-4-3 | Class 1 |
External reset possible | no |
With fuse | no |
IP protection) | IP55 |
Supports protocol for TCP / IP | no |
Supports protocol for PROFIBUS | no |
Supports protocol for CAN | no |
Supports protocol for INTERBUS | no |
Supports protocol for ASI | no |
Supports protocol for MODBUS | no |
Supports data highway protocol | no |
Supports protocol for DeviceNet | no |
Supports protocol for SUCONET | no |
Supports protocol for LON | no |
Supports protocol for PROFINET IO | no |
Supports protocol for PROFINET CBA | no |
Supports protocol for SERCOS | no |
Supports protocol for EtherNet / IP | no |
Supports protocol for DeviceNet Safety | no |
Supports protocol for INTERBUS safety | no |
Supports protocol for PROFIsafe | no |
Supports protocol for SafetyBUS p | no |
Width | 175 mm |
Height | 165 mm |
Depth | 177 mm |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Google Analytics
Partner program
Custom tracking