Surge protection device for signal circuit PT-IQ-1X2+F-24DC-PT

Phoenix - PT-IQ-1X2+F-24DC-PT - Surge protection device for signal circuit PT-IQ-1X2+F-24DC-PT
Photo source: fig. possibly similar
Photo source: fig. possibly similar
PT-IQ-1X2+F-24DC-PT 2801256 4046356766395 EAN/GTIN DE 50738265 WEEE

$117.83 excl. VAT
$224.68 (-47.56% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Overvoltage protection device for signal circuit PT-IQ-1X2+F-24DC-PT Rated voltage DC 24 ... 24V,... more
Surge protection device for signal circuit PT-IQ-1X2+F-24DC-PT – Phoenix – 2801256 – 4046356766395: Overvoltage protection device for signal circuit PT-IQ-1X2+F-24DC-PT Rated voltage DC 24 ... 24V, maximum continuous voltage AC 21V, maximum continuous voltage DC 30V, rated discharge current (8/20) 10kA, rated load current 1A, protection level wire/wire 55V , line/earth protection level 1000V, line/signal ground protection level 600V, signal ground/protective ground protection level 600V, limit frequency 1.1MHz, other type of installation, connection 1 terminal, arrester monitoring, optical signaling on the device, overvoltage protection, consisting of protective plug and base element, with integrated multi-stage status display on the module for a 2-wire floating signal circuit. Indirect grounding via gas discharge tube.
... more
Rated voltage DC 24V
Highest continuous voltage AC 21V
Highest continuous voltage DC 30 V
Nominal discharge current (8/20) 10 kA
Nominal load current 1 A
Protection level wire / core 55V
Protection level core / earth 1000V
Protection level wire / signal ground 600V
Protection level Signalground / Protectiveground 600V
Cut-off frequency 1.1 MHz
Mounting other
Connection 1 Clamp
SPD yes
With telecommunication contact no
Signaling on the device optical
Explosion-tested version no