Isolation amplifier Type of power supply Other, Rated supply voltage at AC 24 ... 230V, Rated... more
Isolation amplifier MACX MCR-UI-UI-SP-NC – Phoenix – 2811556 – 4046356467001: Isolation amplifier Type of power supply Other, Rated supply voltage at AC 24 ... 230V, Rated supply voltage at DC 12 ... 24V, Number of input ranges -60 mV ... +60 mV 1, Number of input ranges -100 mV ... +100 mV 1, Number of input ranges -300 mV ... +300 mV 1, Number of input ranges -500 mV ... +500 mV 1, Number of input ranges -1 V ... +1 V 1, Number of input ranges -2 V ... +2 V 1, Number of input ranges -2.5 V ... +2.5 V 0, Number of input ranges -5 V ... +5 V 1, Number of input ranges -10 V ... +10 V 1, Number of input ranges -20 V ... +20 V 1, Number of input ranges 0 mV ... 60 mV 1, Number of input ranges 0 mV ... 100 mV 1, Number of input ranges 0 mV ... 200 mV 1, Number of input ranges 0 mV ... 300 mV 1, Number of input ranges 0 mV ... 500 mV 1, Number of input ranges 0 V ... 1 V 1, Number of input ranges 0 V ... 2 V 1, Number of input ranges 0 V ... 2.5 V 0, Number of input ranges 0 V ... 5 V 1, Number of input ranges 0 V ... 10 V 1, Number of input ranges 0 V ... 20 V 1, Number of input ranges 0 V ... 24 V 0, Number of input ranges 0 V ... 30 V 1, Number of input ranges 1 V ... 5 V 1, Number of input ranges 2 V ... 10 V 1, Number of input ranges +5 V ... -5 V 0, Number of input ranges +10 V ... -10 V 0, Number of input ranges 5 V ... 0 V 0, Number of input ranges 5 V ... 1 V 0, Number of input ranges 10 V ... 0 V 0, Number of input ranges 10 V ... 2 V 0, Number of input ranges 0 mA ... 5 mA 1, Number of input ranges 0 mA ... 10 mA 1, Number of input ranges 0 mA ... 20 mA 1, Number of input ranges 4 mA ... 20 mA 1, Number of input ranges -5 mA ... +5 mA 1, Number of input ranges -10 mA ... +10 mA 1, Number of input ranges -20 mA ... +20 mA 1, Number of input ranges 20 mA ... 0 mA 0, Number of input ranges 20 mA ... 4 mA 0, Number of output ranges -60 mV ... +60 mV 0, Number of output ranges -100 mV ... +100 mV 0, Number of output ranges -300 mV ... +300 mV 0, Number of output ranges -500 mV ... +500 mV 0, Number of output ranges -1 V ... +1 V 0, Number of output ranges -2 V ... +2 V 0, Number of output ranges -2.5 V ... +2.5 V 1, Number of output ranges -5 V ... +5 V 1, Number of output ranges -10 V ... +10 V 1, Number of output ranges -20 V ... +20 V 0, Number of output ranges 0 mV ... 60 mV 0, Number of output ranges 0 mV ... 100 mV 0, Number of output ranges 0 mV ... 200 mV 0, Number of output ranges 0 mV ... 300 mV 0, Number of output ranges 0 mV ... 500 mV 0, Number of output ranges 0 V ... 1 V 0, Number of output ranges 0 V ... 2 V 0, Number of output ranges 0 V ... 2.5 V 1, Number of output ranges 0 V ... 5 V 1, Number of output ranges 0 V ... 10 V 1, Number of output ranges 0 V ... 20 V 0, Number of output ranges 0 V ... 24 V 0, Number of output ranges 0 V ... 30 V 0, Number of output ranges 1 V ... 5 V 1, Number of output ranges 2 V ... 10 V 1, Number of output ranges +5 V ... -5 V 0, Number of output ranges +10 V ... -10 V 0, Number of output ranges 5 V ... 0 V 0, Number of output ranges 5 V ... 1 V 0, Number of output ranges 10 V ... 0 V 0, Number of output ranges 10 V ... 2 V 0, Number of output ranges 0 mA ... 5 mA 1, Number of output ranges 0 mA ... 10 mA 1, Number of output ranges 0 mA ... 20 mA 1, Number of output ranges 4 mA ... 20 mA 1, Number of output ranges -5 mA ... +5 mA 1, Number of output ranges -10 mA ... +10 mA 1, Number of output ranges -20 mA ... +20 mA 1, Number of output ranges 20 mA ... 0 mA 0, Number of output ranges 20 mA ... 4 mA 0, Number of channels 1, Galvanic separation between input and output, Galvanic separation between supply voltage and all other current circuits, Height 99mm, Width 12,6mm, Depth 114,5mm, Power consumption 0,7W, Load 600 ... 1000Ohm, Operation temperature -20 ... 70°C, Temperature drift 0,0075%/K, Construction type of device Built-in device, Type of electric connection Other, Mounting method Other, Degree of protection (IP) IP20
... more
Type of power supply other
Rated supply voltage for AC 24..230 V
Rated supply voltage for DC 12..24 V
Number of input ranges -60 mV ... +60 mV 1
Number of input ranges -100 mV ... +100 mV 1
Number of input ranges -300 mV ... +300 mV 1
Number of input ranges -500 mV ... +500 mV 1
Number of input ranges -1 V ... +1 V 1
Number of input ranges -2 V ... +2 V 1
Number of input ranges -5 V ... +5 V 1
Number of input ranges -10 V ... +10 V 1
Number of input ranges -20 V ... +20 V 1
Number of input ranges 0 mV ... 60 mV 1
Number of input ranges 0 mV ... 100 mV 1
Number of input ranges 0 mV ... 200 mV 1
Number of input ranges 0 mV ... 300 mV 1
Number of input ranges 0 mV ... 500 mV 1
Number of input ranges 0 V ... 1 V 1
Number of input ranges 0 V ... 2 V 1
Number of input ranges 0 V ... 5 V 1
Number of input ranges 0 V ... 10 V 1
Number of input ranges 0 V ... 20 V 1
Number of input ranges 0 V ... 30 V 1
Number of input ranges 1 V ... 5 V 1
Number of input ranges 2 V ... 10 V 1
Number of input ranges 0 mA ... 5 mA 1
Number of input ranges 0 mA ... 10 mA 1
Number of input ranges 0 mA ... 20 mA 1
Number of input ranges 4 mA ... 20 mA 1
Number of input ranges -5 mA ... +5 mA 1
Number of input ranges -10 mA ... +10 mA 1
Number of input ranges -20 mA ... +20 mA 1
Number of output ranges -2.5 V ... + 2.5 V 1
Number of output ranges -5 V ... +5 V 1
Number of output ranges -10 V ... +10 V 1
Number of output ranges 0 V ... 2.5 V 1
Number of output ranges 0 V ... 5 V 1
Number of output ranges 0 V ... 10 V 1
Number of output ranges 1 V ... 5 V 1
Number of output ranges 2 V ... 10 V 1
Number of output ranges 0 mA ... 5 mA 1
Number of output ranges 0 mA ... 10 mA 1
Number of output ranges 0 mA ... 20 mA 1
Number of output ranges 4 mA ... 20 mA 1
Number of output ranges -5 mA ... +5 mA 1
Number of output ranges -10 mA ... +10 mA 1
Number of output ranges -20 mA ... +20 mA 1
Amount of channels 1
Alarm output no
Intrinsically safe according to EN 60947-5-6 NAMUR no
Galvanic isolation between the inputs no
Height 116.84 mm
Width 12.6 mm
Depth 113.7 mm
Power consumption 0.7 W
Burden 600000..1000000 Ohm
Operating temperature -20..70 °C
Temperature drift 0.0075 %/K
Device type Built-in device
Type of electrical connection other
Mounting other
Degree of protection (IP) IP20