Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP

Phoenix - MACX MCR-SL-I-IILPSP - Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MACX MCR-SL-I-IILPSP 2905279 4046356944397 EAN/GTIN DE 50738265 WEEE

$216.65 excl. VAT
$339.37 (-36.16% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Passive isolator 2-way 0(4)mA-20 mA MACX MCR-SL-I-IILPSP Number of input ranges -60 mV ... +60 mV... more
Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP – Phoenix – 2905279 – 4046356944397: Passive isolator 2-way 0(4)mA-20 mA MACX MCR-SL-I-IILPSP Number of input ranges -60 mV ... +60 mV 0, number of input ranges -100 mV ... +100 mV 0, number of Input ranges -300 mV ... +300 mV 0, number of input ranges -500 mV ... +500 mV 0, number of input ranges -1 V ... +1 V 0, number of input ranges -2 V ... + 2 V 0, number of input ranges -2.5 V ... +2.5 V 0, number of input ranges -5 V ... +5 V 0, number of input ranges -10 V ... +10 V 0, Number of input ranges -20 V ... +20 V 0, Number of input ranges 0 mV ... 60 mV 0, Number of input ranges 0 mV ... 100 mV 0, Number of input ranges 0 mV ... 200 mV 0, Number of input ranges 0 mV ... 300 mV 0, number of input ranges 0 mV ... 500 mV 0, number of input ranges 0 V ... 1 V 0, number of input ranges 0 V ... 2 V 0, number of Input ranges 0 V ... 2.5 V 0, number of input ranges 0 V ... 5 V 0, number of input ranges 0 V ... 10 V 0, number of input ranges 0 V ... 20 V 0, number of Input ranges 0 V ... 24 V 0, number of input ranges 0 V ... 30 V 0, number of input ranges 1 V ... 5 V 0, number of input ranges 2 V ... 10 V 0, number of input ranges + 5 V ... -5 V 0, number of input areas +10 V ... -10 V 0, number of input areas 5 V ... 0 V 0, number of input areas 5 V ... 1 V 0, number of Input ranges 10 V ... 0 V 0, number of input ranges 10 V ... 2 V 0, number of input ranges 0 mA ... 5 mA 0, number of input ranges 0 mA ... 10 mA 0, number of input ranges 0 mA ... 20 mA 1, number of input ranges 4 mA ... 20 mA 1, number of input ranges -5 mA ... +5 mA 0, number of input ranges -10 mA ... +10 mA 0, number of Input ranges -20 mA ... +20 mA 0, number of input ranges 20 mA ... 0 mA 0, number of input ranges 20 mA ... 4 mA 0, number of output ranges -60 mV ... +60 mV 0, Number of output ranges -100 mV ... +100 mV 0, Number of output ranges -300 mV ... +300 mV 0, Number of output ranges -500 mV ... +500 mV 0, Number of output ranges -1 V .. +1 V 0, number of output ranges -2 V ... +2 V 0, number of output ranges -2.5 V ... +2.5 V 0, number of output ranges -5 V ... +5 V 0, number of output ranges -10 V ... +10 V 0, number of output ranges -20 V ... +20 V 0, number of output ranges 0 mV ... 60 mV 0, number of output ranges 0 mV ... 100 mV 0, number of output ranges 0 mV ... 200 mV 0, number of output ranges 0 mV ... 300 mV 0, number of output ranges 0 mV ... 500 mV 0, number of output ranges 0 V ... 1 V 0, number of output ranges 0 V ... 2 V 0, number of output ranges 0 V ... 2.5 V 0, number of output ranges 0 V ... 5 V 0, number of output ranges 0 V ... 10 V 0, number of output ranges 0 V ... 20 V 0, number of output ranges 0 V ... 24 V 0, number of output ranges 0 V ... 30 V 0, number of output ranges 1 V ... 5 V 0, Number of output ranges 2 V ... 10 V 0, number of output ranges +5 V ... -5 V 0, number of output ranges +10 V ... -10 V 0, number of output ranges 5 V ... 0 V 0, number of output ranges 5 V ... 1 V 0, number of output ranges 10 V ... 0 V 0, number of output ranges 10 V ... 2 V 0, number of output ranges 0 mA ... 5 mA 0, Number of output ranges 0 mA ... 10 mA 0, Number of output ranges 0 mA ... 20 mA 1, Number of output ranges 4 mA ... 20 mA 1, Number of output ranges -5 mA ... +5 mA 0, Number of output ranges -10 mA ... +10 mA 0, Number of output ranges -20 mA ... +20 mA 0, Number of output ranges 20 mA ... 0 mA 0, Number of output ranges 20 mA ... 4 mA 0, number of channels 1, height 116.59mm, width 12.78mm, depth 113.7mm, burden 1375000 ... 1375000Ohm, operating temperature -40 ... 85°C, temperature drift 0.002%/K, device design built-in device, version of electrical connection other, mounting type other, protection class (IP) IP20, single-channel input loop-powered 2-way isolator with pluggable connection technology for galvanic isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
... more
Number of input ranges 0 mA ... 20 mA 1
Number of input ranges 4 mA ... 20 mA 1
Number of output ranges 0 mA ... 20 mA 1
Number of output ranges 4 mA ... 20 mA 1
Amount of channels 1
Alarm output no
Intrinsically safe according to EN 60947-5-6 NAMUR no
Galvanic isolation between the inputs no
Height 116 mm
Width 12.5 mm
Depth 114.5 mm
Burden 2,39999999 A
Operating temperatur -40..85 °C
Temperature drift 0.002 %/K
Device Type Built-in device
Execution of the electrical connection other
Mounting Snap-on mounting rail
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.