Fieldbus digital module 8 In / 0 Out - Decentralized I / O device 24V DC AXL E IOL DI8 M12 6P

Phoenix - AXL E IOL DI8 M12 6P - Fieldbus digital module 8 In / 0 Out - Decentralized I / O device 24V DC AXL E IOL DI8 M12 6P
Photo source: fig. possibly similar
Photo source: fig. possibly similar
AXL E IOL DI8 M12 6P 2702658 4055626279671 EAN/GTIN

$126.56 excl. VAT

22-23 days* (USA)

Fieldbus digital module, Number of digital inputs 8th, Digital inputs configurable no, Digital... more
Fieldbus digital module 8 In / 0 Out - Decentralized I / O device 24V DC AXL E IOL DI8 M12 6P – Phoenix – 2702658 – 4055626279671: Fieldbus digital module, Number of digital inputs 8th, Digital inputs configurable no, Digital outputs configurable no, Input current for signal 1 0,0024 mA, Permissible voltage at the input 24..30 V, Type of digital output without, Short-circuit protection, outputs available no, Number of HW interfaces, other 1, With optical interface no, Supports protocol for TCP/IP no, Supports protocol for PROFIBUS no, Supports protocol for CAN no, Supports protocol for INTERBUS no, Supports protocol for ASI no, Supports protocol for KNX no, Supports protocol for MODBUS no, Supports data highway protocol no, Supports protocol for DeviceNet no, Supports protocol for SUCONET no, Supports protocol for LON no, Supports protocol for PROFINET IO no, Supports protocol for PROFINET CBA no, Supports protocol for SERCOS no, Supports protocol for Ethernet/IP no, Supports protocol for DeviceNet Safety no, Supports protocol for INTERBUS safety no, Supports protocol for PROFIsafe no, Supports protocol for SafetyBUS p no, IO link master yes, System component yes, Degree of protection (IP) IP65, Type of electrical connection other, Delay time with signal change 0ms, Mounting rail installation possible no, Wall/direct mounting possible yes, Front installation possible no, Rack mounting possible no, Suitable for safety functions no, SIL according to IEC 61508 without, Performance level according to EN ISO 13849-1 without, Associated equipment (Ex ia) no, Associated equipment (Ex ib) no, Explosion protection category for gas without, Explosion protection category for dust other, Width 60 mm, Height 141 mm, Depth 20 mm
... more
Number of digital inputs 8th
Digital inputs configurable no
Digital outputs configurable no
Input current at signal 1 0,9 kA
Permissible voltage at the input 24..30 V
Type of digital output without
Short-circuit protection, outputs available no
Number of HW interfaces other 1
With optical interface no
Supports protocol for TCP / IP no
Supports protocol for PROFIBUS no
Supports protocol for CAN no
Supports protocol for INTERBUS no
Supports protocol for ASI no
Supports protocol for KNX no
Supports protocol for MODBUS no
Supports data highway protocol no
Supports protocol for DeviceNet no
Supports protocol for SUCONET no
Supports protocol for LON no
Supports protocol for PROFINET IO no
Supports protocol for PROFINET CBA no
Supports protocol for SERCOS no
Supports protocol for EtherNet / IP no
Supports protocol for DeviceNet Safety no
Supports protocol for INTERBUS safety no
Supports protocol for PROFIsafe no
Supports protocol for SafetyBUS p no
IO-Link master yes
System component yes
IP protection) IP65
Execution of the electrical connection other
Delay time with signal change 0ms
Rail mounting possible no
Wall / direct mounting possible yes
Front installation possible no
Rack mounting possible no
Suitable for safety functions no
SIL according to IEC 61508 without
Performance level according to EN ISO 13849-1 without
Associated equipment (Ex ia) no
Associated equipment (Ex ib) no
Explosion protection category for gas without
Explosion protection category for dust other
Width 60 mm
Height 141 mm
Depth 20 mm

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Fieldbus digital module 8 In / 0 Out - Decentralized I / O device 24V DC AXL E IOL DI8 M12 6P"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.