Lightning Controller Rail 3-pin. 255V - Combined arrester for power systems MCF75-NAR-TNC

OBO - MCF75-NAR-TNC - Lightning Controller Rail 3-pin. 255V - Combined arrester for power systems MCF75-NAR-TNC
Photo source: fig. possibly similar
Photo source: fig. possibly similar
MCF75-NAR-TNC 5096982 4012196608768 EAN/GTIN DE 64419409 WEEE

$616.41 excl. VAT
$1,201.58 (-48.7% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Lightning Controller Rail 3-pin. 255V MCF75-NAR-TNC TN system type, TN-C system type, TN-CS... more
Lightning Controller Rail 3-pin. 255V - Combined arrester for power systems MCF75-NAR-TNC – OBO – 5096982 – 4012196608768: Lightning Controller Rail 3-pin. 255V MCF75-NAR-TNC TN system type, TN-C system type, TN-CS system type, TN-S system type, TT system type, number of poles 3, lightning impulse current (10/350 µs) 25kA, maximum continuous voltage AC 255V, nominal voltage AC 230V, protection level 1 5kV, protection level LN 1.5kV, protection level N-PE 1.5kV, follow current extinguishing capacity 50kA, max. conductor cross-section solid (single/stranded) 35mm², max optical, test class type 1 and 2, The MCF75-NAR combination arrester type 1+2 for lightning protection equipotential bonding according to VDE 0185-305 (IEC 62305) is suitable for use in the pre-counter area according to VDE-AR-N 4100. Areas of application of the MCF75-NAR are Buildings with lightning protection or overhead line feed in TN-C systems. It is installed on 40 mm busbars in the connection compartment on the mains side. The protection level of <=1.5 kV protects the end devices in the system. The lightning current discharge capacity is 75 kA (10/350) in total and 25 kA (10/350) per pole, follow current extinguishing up to 50 kA with a max. back-up fuse up to 315 A gL/gG.
... more
Network shape TN yes
Mains form TN-C yes
Lightning impulse current (10/350 µs) 25 kA
Nominal discharge current (8/20) 25 kA
Highest continuous voltage AC 255V
Rated voltage AC 230V
Protection level 1.5 kV
Mounting Bus bar
Size other
Signaling on the device optical
IP protection) IP20

Rate item