Level guard - Level relay conductive sensor ENW-E12 24VAC 2W

Metz - ENW-E12 24VAC 2W - Level guard - Level relay conductive sensor ENW-E12 24VAC 2W
Photo source: fig. possibly similar
Photo source: fig. possibly similar
ENW-E12 24VAC 2W 11030810 4250184121251 EAN/GTIN DE 87494433 WEEE

Our best price
$66.66 excl. VAT
$140.04 (-52.4% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Level monitor ENW-E12 24VAC 2W Design of the electrical connection Screw connection, Rated... more
Level guard - Level relay conductive sensor ENW-E12 24VAC 2W – Metz – 11030810 – 4250184121251: Level monitor ENW-E12 24VAC 2W Design of the electrical connection Screw connection, Rated control supply voltage Us at AC 50 Hz 24 ... 24V, Type of voltage for actuation AC, Number of electrode inputs 3, Min. adjustable ON delay time 0s, Max. permissible ON delay time 0s, Min. adjustable OFF delay time 0s, max. permissible off-delay time 0s, response sensitivity adjustable, number of contacts as opener 0, number of contacts as closer 0, number of contacts as changer 2, physical measuring principle conductive, width 22.5mm, height 75mm, depth 100mm, the level monitor is used for level or leakage monitoring of all conductive non-flammable media. The response point can be set using a proportional potentiometer. As a guard, the device works with an electrode (EO) and the ground connection (EM), e.g. B. for messages of minimum or maximum, as overflow or dry-running protection for submersible pumps. An additional electrode (EU) is recommended if the surface of the level is unstable. As a two-point controller, the device controls pumps or valves for the automatic filling or emptying of containers with the electrodes EO, EU and ground connection EM. A container wall that is conductive to the medium can also be used as a ground connection. When connecting 2 electrodes, the connections B2 and B3 must be bridged! Variants: 230 V AC or 24 V AC
... more
Voltage type for actuation AC
With removable clamps no
Number of electrode inputs 3
Sensitivity adjustable yes
Number of contacts as changer 2
Physical measuring principle conductive
Cascadable no
Width 22.5 mm
Height 75 mm
Depth 100 mm