Reducer for Ex-Area, DN180>140 - Reduction piece for ventilation system REM 18/14 Ex

Maico - REM 18/14 Ex - Reducer for Ex-Area, DN180>140 - Reduction piece for ventilation system REM 18/14 Ex
Photo source: fig. possibly similar
Photo source: fig. possibly similar
REM 18/14 Ex 0055.0304 4012799553045 EAN/GTIN DE 78107228 WEEE

Our best price
$68.96 excl. VAT
$100.82 (-31.6% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Reducer f.Ex-Ber., DN180>140 REM 18/14 Ex, material=other, height=179 mm, width=179 mm, reducers... more
Reducer for Ex-Area, DN180>140 - Reduction piece for ventilation system REM 18/14 Ex – Maico – 0055.0304 – 4012799553045: Reducer f.Ex-Ber., DN180>140 REM 18/14 Ex, material=other, height=179 mm, width=179 mm, reducers for installing tube fans in tube systems. REM ...: Made of impact-resistant plastic. REM ... Ex: Made of antistatic material (metal) for use in potentially explosive atmospheres. Item: REM 18/14 Ex, installation location: pipe, material: metal, weight: 0.6 kg, reduction to nominal width: 180 mm / 140 mm, width: 179 mm, height: 179 mm, depth: 165 mm, suitable for Box fan: no, Suitable for roof fans: no, Suitable for duct fans: yes, Suitable for heat recovery systems: no, Suitable for wall-mounted fans: no, Suitable for built-in wall fans: no, Suitable for residential building fans: no, Suitable for centrifugal fans: no, Suitable for circulation fans: no
... more
Material of duct other
Nominal width duct connection 1 179 mm
Nominal height duct connection 1 179 mm
Length 165 mm