Residual current circuit breaker, 2-pole, 25A 10mA CCA225D

CCA225D 3250611618270 EAN/GTIN DE 23692311 WEEE

Our best price
$55.28 excl. VAT
$100.13 (-44.79% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI circuit breaker 2P 25A 10mA CCA225D number of poles 2, rated voltage 230V, rated current 25A,... more
Residual current circuit breaker, 2-pole, 25A 10mA CCA225D – Hager – 3250611618270: FI circuit breaker 2P 25A 10mA CCA225D number of poles 2, rated voltage 230V, rated current 25A, rated residual current 10mA, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, DIN rail mounting type, residual current type A, short-circuit strength (Icw) 6kA, surge current strength 0.25kA, frequency 50 Hz, additional equipment possible, degree of protection (IP) IP20, width in pitch units 2, installation depth 70mm, ambient temperature during operation -25... 40°C, degree of pollution 2, connectable conductor cross-section stranded 1... 16mm², connectable conductor cross-section solid 1... 25mm², residual current circuit breaker 2 pole 6kA 25A 10mA type A. Residual current circuit breaker (FI) according to EN 61008-1, DIN EN 61008-2-1, VDE 0664 part 10 + 11, protection against accidental contact IP2x according to DIN VDE 0106 part 100. Suitable for Subsequent attachment of additional equipment (assembly without tools). Wire push-in protection terminals, bottom bi-connect terminals, external blue test button. All products with VDE mark. Labeling option directly on the device.
... more
Number of poles 2
Rated voltage 230V
Rated current 25 A
Rated fault current 0.01A
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Mounting DIN rail
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 6 kA
Surge current resistance 0.25 kA
Voltage AC
With locking device yes
Frequency 50 Hz
Additional equipment possible yes
IP protection) IP20
Width in division units 2
Depth 70 mm
Pollution degree 2
Explosion protection no