Residual current circuit breaker with line protection two-pole C-16A 30mA ADS966D

ADS966D 3250611068228 EAN/GTIN DE 23692311 WEEE

Our best price
$53.15 excl. VAT
$138.92 (-61.74% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
RCBO 1P+N 6kA C-16A 30mA ADS966D number of poles (total) 2, number of fused poles 1, rated... more
Residual current circuit breaker with line protection two-pole C-16A 30mA ADS966D – Hager – 3250611068228: RCBO 1P+N 6kA C-16A 30mA ADS966D number of poles (total) 2, number of fused poles 1, rated voltage 240V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated current 16A, rated residual current 0.03A, residual current type A, Energy limitation class 3, rated breaking capacity according to IEC 60947-2 6kA, rated short-circuit breaking capacity Icn according to EN 61009-1 6kA, instantaneous switch-off characteristic, surge current strength 0.25kA, type of voltage AC, frequency 50 Hz, tripping characteristic C, switching neutral conductor, overvoltage category 3, degree of pollution 2, ambient temperature during the Operating -25... 40°C, width in pitch units 2, installation depth 68mm, suitable for flush-mounted installation, degree of protection (IP) IP20, residual current circuit breaker 1P+N 6kA C-characteristic 16A 30mA type A QC. Residual current circuit breaker with QuickConnect terminal according to DIN EN 60898-1, VDE 0641-11, up to 20 A at the outlet and up to 63 A at the inlet. Touch protection DIN VDE 0106 part 100, blue test button and residual current display. Easy individual removal from the phase busbar assembly. With VDE mark. Suitable for retrofitting additional equipment. Labeling option directly on the device.
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 240V
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Rated current 16 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated switch-off capacity according to IEC 60947-2 6 kA
turn-off characteristic instantaneously
Surge current resistance 0.25 kA
Voltage AC
Frequency 50 Hz
Release characteristic C
Coupling neutral conductor yes
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 68 mm
Flush mounting yes
False triggering protection no
IP protection) IP2X