Mains disconnector, mains disconnector, self-learning, 16A, 250V AC FR12-230V

FR12-230V 22100231 4010312203255 EAN/GTIN DE 30298319 WEEE

Our best price
$47.35 excl. VAT
$93.14 (-49.16% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Field disconnector for series. 1S 16A, self-learning. FR12-230V rated voltage 230V, rated current... more
Mains disconnector, mains disconnector, self-learning, 16A, 250V AC FR12-230V – Eltako – 22100231 – 4010312203255: Field disconnector for series. 1S 16A, self-learning. FR12-230V rated voltage 230V, rated current 10A, rated frequency 50 ... 50Hz, max. incandescent lamp load 2300W, max. fluorescent lamp load 500VA, max. fluorescent lamp load (duo circuit) 1000VA, max. fluorescent lamp load (parallel compensated) 500VA, max. switching current (cos phi = 0.6) 16A, current switch-on threshold 20 ... 20mA, DC monitoring voltage, DIN rail mounting type, width in modular widths 3, installation depth 26mm, degree of protection (IP) IP20, self-learning field disconnector. self-learning Standby loss only 0.8 watts. The latest hybrid technology combines the advantages of wear-free electronic control with the high switching capacity of special relays. The field isolation switch interrupts the power supply after the downstream consumers have been switched off and thus prevents interfering electromagnetic fields. Up to a current consumption of 200mA, small consumers are permitted, which do not prevent field disconnection after larger consumers have been switched off. The limit value does not have to be set manually, but is learned by the FR12 itself using a patented process. Consumers with a current consumption of more than 200mA are always defined as consumers that should cause the mains voltage to be switched on. As long as no larger consumers are switched on, the monitored circuit remains 1-pole switched off from the mains. Neutral and protective conductors are not switched to prevent an antenna effect. An adjustable DC voltage with low residual ripple is available for monitoring. Therefore, bridging the work contact is not permitted and will destroy the device. When a consumer is switched on, the field disconnector switches on the monitored phase conductor with a delay of approx. 1 second and the LED lights up red.
... more
Rated voltage 230V
Rated current 10 A
Rated frequency 50 Hz
Max. Incandescent lamp load 2300 W
Max. Fluorescent lamp load 500 VA
Switch-on threshold current 20 mA
Monitoring voltage DC
Mounting DIN rail
Width in division units 3
Depth 26 mm
IP protection) IP20