Surge dimmer switch - Dimmer flush mounted EUD61NPN-230V

EUD61NPN-230V 61100802 4010312109564 EAN/GTIN DE 30298319 WEEE

Our best price
$41.06 excl. VAT
$77.24 (-46.84% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Pulse dimmer switch EUD61NPN-230V composition other, operating type touch operation, dimming... more
Surge dimmer switch - Dimmer flush mounted EUD61NPN-230V – Eltako – 61100802 – 4010312109564: Pulse dimmer switch EUD61NPN-230V composition other, operating type touch operation, dimming leading edge, dimming trailing edge, load type universal, light value memory, can be used with button, type of installation flush-mounted, type of fastening with screw, material plastic, material quality thermoplastic, halogen-free, surface other, design of Surface matt, color blue, nominal voltage 230 ... 230V, control voltage 230 ... 230V, connection type screw terminal, wire cross-section 4 ... 4mm², device width 45mm, device height 45mm, device depth 18mm, min. depth of device box 18mm, universal dimmer switch. Power MOSFET up to 400W. Automatic lamp detection. Standby loss only 0.1 watts. Minimum brightness or dimming speed adjustable. With children's room and snooze switch. For flush mounting. 45mm long, 45mm wide, 18mm deep. Universal dimmer switch for lamps up to 400W, depending on the ventilation conditions. Dimmable energy-saving lamps ESL and dimmable 230V LED lamps also depend on the lamp electronics. Switching at zero crossing with soft on and soft off to protect the lamp. Control voltage, supply voltage and switching voltage 230V. No minimum load required. Short control commands switch on/off, permanent control changes the brightness up to the maximum value. An interruption of the control changes the dimming direction. The set brightness level is saved when the device is switched off (memory). In the event of a power failure, the switching position and the brightness level are saved and, if necessary, switched on when the supply voltage returns. Automatic electronic overload protection and over-temperature shutdown. The upper %lamp/dim-speed rotary switch can be used to set either the dimming speed or the minimum brightness (fully dimmed). The duration of soft on and soft off is also changed with the dimming speed. During operation, the lower rotary switch determines whether the automatic lamp recognition should take effect or special comfort positions: AUTO allows dimming of all lamp types. EC1 is a comfort position for energy-saving lamps, which, due to their design, have to be switched on with an increased voltage so that they can also be safely switched on again when dimmed when cold. EC2 is a comfort position for energy-saving lamps which, due to their construction, cannot be switched on again when they are dimmed. Therefore memory is switched off in this position. LC1 is a comfort position for LED lamps which, due to their construction, cannot be dimmed down far enough to AUTO (trailing edge) and must therefore be forced to phase control. LC2 and LC3 are comfort positions for LED lamps like LC1 but with different dimming curves. No inductive (wound) transformers may be used in positions EC1, EC2, LC1, LC2 and LC3. In addition, the maximum number of dimmable LED lamps can be lower than in the AUTO position due to the design. With children's room circuit: When switching on by pressing the button for a longer period of time, the brightness level is switched on after approx. With snooze function: A double impulse dims the lighting from the current dimming setting down to minimum brightness and then switches it off. The maximum dimming time of 60 minutes depends on the current dimming setting and the set minimum brightness and can be shortened accordingly. You can switch off at any time during the dimming process by briefly pressing the button. A long press during the dimming process dims up and ends the snooze mode. L loads (inductive loads, e.g. wound transformers) and C loads (capacitive loads, e.g. electronic transformers and LED lamps) must not be mixed. R loads (ohmic loads, e.g. 230V incandescent and halogen lamps) can be added as desired.
... more
Compilation other
Of operation Tip button
App control via Bluetooth no
Dimming Phase control yes
Dimming Phase section yes
Series dimmer no
Load type universal
Extension input no
Light value memory yes
Suitable with button yes
Usable with motion detector no
Suitable with presence detector no
Usable with timer / timer no
Suitable with radio button no
Usable with IR button no
Mounting Flush
Mounting Fastening with screw
Material Plastic
Material quality Thermoplastic
Halogen free yes
Surface protection other
Execution of the surface frosted
Colour blue
Transparent no
Nominal voltage 230V
Control voltage 230V
Rated capacity resistive load 400W
Rated capacity inductive load 400 VA
Rated capacity capacitive load 400 VA
Max. switching capacity LED 400W
Connection Screw terminal
Core cross-section 4 mm²
Device width 45 mm
Device height 45 mm
Device depth 18 mm
Min. depth of the device socket 18 mm
Compatible with Apple HomeKit no
Compatible with Google Assistant no
Compatible with Amazon Alexa no
IFTTT support available no