Combined arrester DEHNcombo YPV - Combined arrester for power systems 900070

900070 6942299504521 EAN/GTIN DE 11890845 WEEE

Our best price
$157.73 excl. VAT
$319.56 (-50.64% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Combined arrester DEHNcombo YPV 900070 network type DC, number of poles 2, lightning impulse... more
Combined arrester DEHNcombo YPV - Combined arrester for power systems 900070 – Dehn – 6942299504521: Combined arrester DEHNcombo YPV 900070 network type DC, number of poles 2, lightning impulse current (10/350 µs) 12.5kA, max. PV voltage 1200V, protection level (DC+ - DC-) 3.8kV, protection level (DC+/DC- - PE) 3, 8kV, max. conductor cross-section rigid (single/stranded) 35mm², max. conductor cross-section flexible (finely stranded) 25mm², mounting type DIN rail TH35, size 4 TE, optical signaling on the device, test class type 1 and 2, degree of protection (IP) IP20, multi-pole combi - Arrester type 1 + type 2 for photovoltaic generator circuits DEHNcombo YPV, type 1 + type 2 according to EN 50539-11 with 3-stage DC switching device. Combined disconnection and short-circuiting device. To protect photovoltaic inverters against overvoltages, even in the event of direct lightning strikes. For use in accordance with IEC 60364-7-712:2002-05 (installation of photovoltaic supply systems).
... more
Network form DC yes
Network form IT no
Network shape TN no
Mains form TN-C no
Mains form TN-CS no
Mains form TN-S no
Network shape TT no
Network form other no
Number of poles 2
Lightning impulse current (10/350 µs) 12.5 kA
Max. PV voltage 1200V
Protection level (DC + - DC-) 3.8 kV
Protection level (DC + / DC- - PE) 3.8 kV
Mounting DIN rail TH35
Size 4 TE
Remote signaling no
Signaling on the device optical
Test class Type 1 and 2
Integrated backup fuse no
Voltage switching spark gap technology no
Overcurrent-protected voltage tap-off no
IP protection) IP20