Transformer kilowatt-hour meter 1A A44 552-100

ABB - A44 552-100 - Transformer kilowatt-hour meter 1A A44 552-100
Photo source: fig. possibly similar
Photo source: fig. possibly similar
A44 552-100 2CMA170545R1000 7392696705455 EAN/GTIN DE 91945327 WEEE

Our best price
$578.68 excl. VAT
$1,128.01 (-48.7% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Instrument transformer meter RS485 A44 552-100 Electronic meter type, rated current (In) 1A,... more
Transformer kilowatt-hour meter 1A A44 552-100 – ABB – 2CMA170545R1000 – 7392696705455: Instrument transformer meter RS485 A44 552-100 Electronic meter type, rated current (In) 1A, maximum current (Imax) 6A, rated voltage (Un) NL 57.7 ... 288V, rated voltage (Un) LL 100 ... 500V, frequency 50 ... 60Hz, accuracy class C, Polart four-wire, measuring transducer version, energy type active and reactive power, suitable for import/supply, tariff design multi-tariff, tariff control internal/external, measurement type load profile, backstop, calibrated, approval Measuring Instruments Directive, pulse output electrical, pulse type S0, pulse rate 5000 ... 5000Imp/kWh (kvarh), display type digital, mounting type REG, width in division units 7, design of the interface RS-485, number of digits 7, protection class (IP) IP20, protection class (NEMA) other, three-phase meter for measuring a Three-wire or four-wire three-phase network via a CTVT converter connection (configurable converter ratio for current and voltage) up to a maximum of 6 A. The following values are output via a backlit display with up to 7 digits level: active energy (class 0.5) and reactive energy (class 2) for import and export, power, currents, voltages (LL, LN), frequency, cos phi, power factor and apparent power (per phase and total). Communication can take place via the integrated RS485 or infrared interface. The energy meter has 4 individually programmable inputs/outputs. The output can be used either as a pulse output or as an alarm output (up to 25 alarm values). The inputs are used to control the tariffs or to count external pulses. In addition, the meter records up to 4 tariffs. The energy meter measures currents and voltages up to the 16th harmonic and uses it to calculate the total harmonic distortion. Meter is calibrated according to MID and approved according to IEC. The installation width is 7 DIN modules.
... more
Counter type electronic
Rated current (in) 6A
Maximum current (Imax) 6A
Rated voltage (Un) NL 57,7..288 V
Rated voltage (Un) LL 100..500 V
Frequency 50..60 Hz
Accuracy class C
Polart Four conductors
Execution Transducers
Of energy Active and reactive power
Suitable for Purchase / delivery
Rate design Multi-tariff
Tariff control internal / external
Measurement type load profile yes
Backstop yes
Calibrated yes
Admission Measuring Instruments Directive
Pulse output electrical
Pulse type S0
Pulse rate 5000 Imp/kWh (kvarh)
Display digital
Mounting REG
Width in division units 7
Width 123 mm
Depth 65 mm
Height 26.5 mm
Execution of the interface other
EDL40 signature no
With lock code no
Number of digits 7
IP protection) IP20
Protection class (NEMA) other

Rate item