Three-phase meter M-Bus - Direct kilowatt-hour meter 5A B23 113-100

B23 113-100 2CMA100165R1000 7392696001656 EAN/GTIN DE 91945327 WEEE

Our best price
$181.62 excl. VAT
$336.33 (-46% RRP***)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Three-phase meter M-Bus B23 113-100 Electronic meter type, rated current (In) 5A, maximum current... more
Three-phase meter M-Bus - Direct kilowatt-hour meter 5A B23 113-100 – ABB – 2CMA100165R1000 – 7392696001656: Three-phase meter M-Bus B23 113-100 Electronic meter type, rated current (In) 5A, maximum current (Imax) 65A, rated voltage (Un) NL 220 ... 240V, rated voltage (Un) LL 380 ... 415V, frequency 50 ... 60Hz, accuracy class B, Polart four-wire, direct measurement version, active power energy type, suitable for purchase, one-tariff tariff version, backstop, calibrated, Measuring Instruments Directive approval, electrical pulse output, pulse type S0, pulse rate 1 ... 999999imp/kWh (kvarh), digital display type , REG mounting type, width in module spacing 4, design of the M-Bus interface, number of digits 7, degree of protection (IP) IP20, degree of protection (NEMA) other, three-phase meter for measuring a three-wire or four-wire three-phase network via a direct connection up to a maximum of 65 A The following values are output via a seven-segment display with up to 7 digits: active energy (class 1), power, currents, voltages (LL, LN) and frequency, both per phase and in total. Communication can take place via the integrated M-Bus interface or via the infrared interface for connecting a KNX module. The energy meter has an output. This can be used either as a pulse output to output active energy or as an alarm output. Up to 25 alarm values (threshold values with a time delay) can be set here. The meter is calibrated according to MID and approved according to IEC. The installation width is 4 DIN modules.
... more
Counter type electronic
Rated current (in) 65 A
Maximum current (Imax) 65 A
Rated voltage (Un) NL 220..240 V
Rated voltage (Un) LL 380..415 V
Frequency 50..60 Hz
Accuracy class B
Polart Four conductors
Execution Direct measurement
Of energy Active power
Suitable for Reference
Rate design Single tariff
Measurement type load profile no
Backstop yes
Calibrated yes
Admission Measuring Instruments Directive
Pulse output electrical
Pulse type S0
Pulse rate 59,0909 lm/W
Display digital
Mounting REG
Width in division units 4
Width 70 mm
Depth 65 mm
Height 26.5 mm
Execution of the interface M-Bus
EDL40 signature no
With lock code no
Number of digits 7
IP protection) IP20
Protection class (NEMA) other

Rate item