FI block 4-pin, 40A, 30mA - Residual current circuit breaker module DDA204A-40/0,03

DDA204A-40/0,03 2CSB204101R1400 8012542798101 EAN/GTIN DE 91945327 WEEE

Our best price
$86.01 excl. VAT
$140.54 (-38.8% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI block 4p, 40A,30mA DDA204A-40/0.03 rated voltage 230 ... 400V, rated current 40A, rated fault... more
FI block 4-pin, 40A, 30mA - Residual current circuit breaker module DDA204A-40/0,03 – ABB – 2CSB204101R1400 – 8012542798101: FI block 4p, 40A,30mA DDA204A-40/0.03 rated voltage 230 ... 400V, rated current 40A, rated fault current 0A, max. delay time 0ms, number of poles 4, fault current type A, frequency 50/60 Hz, rated insulation voltage Ui 500V , Rated impulse withstand voltage Uimp 4kV, Connectable conductor cross-section, solid 16 ... 16mm², Connectable conductor cross-section, stranded 16 ... 16mm², With locking device, Degree of protection (IP) IP2X, Ambient temperature during operation -25 ... 55°C, The FI block ( RCU) is for customer installation with circuit breakers of the S200 series. The resulting FI/LS combinations (RCBOs) offer personal and property protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of 1P+N, 2P, 3P, 3P+N or 4P circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet the product standard IEC/EN 61009 Annex G. Areas of application are household, commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. The rated switching capacity when mounting MCB S200 is: 6 kA, S200 M: 10 kA, S200 P: 25 kA.
... more
Nominal voltage 230..400V
Current 40 A
Rated fault current adjustable no
Rated fault current 0.03 A
Max. Delay time 0ms
Delay time adjustable no
Number of poles 4
Fault current type A
Frequency 50/60 Hz
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
False triggering protection no
With locking device yes
IP protection) IP2X