RCBO 10kA, 1p+N - Earth leakage circuit breaker C20/0A DS201MA-C20/0,03AP-R

ABB - DS201MA-C20/0,03AP-R - RCBO 10kA, 1p+N - Earth leakage circuit breaker C20/0A DS201MA-C20/0,03AP-R
Photo source: fig. possibly similar
Photo source: fig. possibly similar
DS201MA-C20/0,03AP-R 2CSR275480R1204 8012542595113 EAN/GTIN DE 91945327 WEEE

$168.65 excl. VAT
$290.08 (-41.86% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Earth leakage circuit breaker C20/0A Number of poles (total) 2, Number of protected poles 1,... more
RCBO 10kA, 1p+N - Earth leakage circuit breaker C20/0A DS201MA-C20/0,03AP-R – ABB – 2CSR275480R1204 – 8012542595113: Earth leakage circuit breaker C20/0A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated current 20A, Rated fault current 0A, Leakage current type Other, Rated short-circuit breaking capacity acc. EN 61009 10kA, Rated short-circuit breaking capacity IEC 60947-2 15kA, Surge current capacity 3kA, Voltage type AC, Frequency 50/60 Hz, Release characteristic C, Concurrently switching N-neutral, Over voltage category 3, Pollution degree 2, Ambient temperature during operating 55 ... 55°C, Width in number of modular spacings 2, Built-in depth 69mm, Degree of protection (IP) IP2X
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 240V
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Rated current 20 A
Rated fault current 0.03 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 10 kA
turn-off characteristic instantaneously
Surge current resistance 3 kA
Voltage AC
Frequency 50/60 Hz
Release characteristic C
Coupling neutral conductor yes
With locking device no
Overvoltage category 3
Pollution degree 2
Width in division units 2
Depth 69 mm
Flush mounting no
False triggering protection no
IP protection) IP20

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "RCBO 10kA, 1p+N - Earth leakage circuit breaker C20/0A DS201MA-C20/0,03AP-R"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.