FS401E-B13/0.03 2CCL562111E0135 7612270108558 EAN/GTIN DE 91945327 WEEE

Our best price
$97.03 excl. VAT
$130.42 (-25.6% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Residual current circuit breaker B FS401E-B13/0.03 number of poles (total) 2, number of fused... more
RCD B - Earth leakage circuit breaker B13/0A FS401E-B13/0.03 – ABB – 2CCL562111E0135 – 7612270108558: Residual current circuit breaker B FS401E-B13/0.03 number of poles (total) 2, number of fused poles 1, rated voltage 230V, rated insulation voltage Ui 500V, rated impulse withstand voltage Uimp 4kV, rated current 13A, rated residual current 0A, residual current type A, energy limitation class 3, rated breaking capacity according to EN 61009 6kA, Rated breaking capacity according to IEC 60947-2 10kA, rated short-circuit breaking capacity Icn according to EN 61009-1 10kA, instantaneous switch-off characteristic, surge current strength 0.3kA, type of voltage AC, frequency 50/60 Hz, tripping characteristic B, with locking device, overvoltage category 3, degree of pollution 2, ambient temperature during operation -25 ... 40°C, width in pitch units 1, installation depth 91mm, degree of protection (IP) IP20, connectable conductor cross-section solid 0.8 ... 35mm², connectable conductor cross-section stranded 0.8 ... 35mm², RCBO (RCBOs) provide personal and property protection as well as protection against electrically ignited avoid fires according to DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection (with I?n = 30 mA) and fire protection (with I?n = 300 mA). They meet the product standard IEC/EN 61009-1 (VDE 0664-20). Contact is made directly via the Smissline TP socket system and the outer conductor contact can be freely selected for single-phase devices (L1, L2 or L3)
... more
Number of poles (total) 2
Number of secured poles 1
Rated voltage 240V
Rated insulation voltage Ui 500V
Rated impulse withstand voltage Uimp 4 kV
Rated current 13 A
Rated fault current 0,02999999 A
Fault current type A
Limiting class 3
Rated breaking capacity according to EN 61009 6 kA
Rated switch-off capacity according to IEC 60947-2 6 kA
turn-off characteristic instantaneously
Surge current resistance 0.25 kA
Voltage AC
Frequency 50/60 Hz
Release characteristic B
Coupling neutral conductor no
With locking device yes
Overvoltage category 3
Pollution degree 2
Width in division units 1
Depth 91 mm
Flush mounting no
False triggering protection no
IP protection) IP20